Accessories And Functional Parts; Sheet Metal Accessories; Functional Parts; General Information - Whirlpool WGGE43 Installation Instructions Manual

Package gas electric furnaces
Table of Contents

Advertisement

3. Remove the burners.
4. Use a bottle brush to clean burner insert and inside of the
burners.
5. Replace burners and manifold, inspect the burner assembly
for proper seating of burners in retention slots.
6. Reconnect electrical power and gas supply.
WARNING
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.

Sheet Metal Accessories

Additional accessories can be purchased to fit specific
application needs. Parts and instructions are available from your
distributor.

Functional Parts

Functional Parts List
Auxiliary Limit Switch
Blower Housing
Circulator Blower Motor
Blower Wheel
Burner
Capacitor
Compressor
Unit
Model
Static CFM
WGGE4324A045M
0.1
Rise Range:
0.2
30º to 60º
0.3
0.4
0.5
0.6
0.7
0.8
20

ACCESSORIES AND FUNCTIONAL PARTS

Flame Roll-out Switch
Flame Sensor
Gas Orifice
Gas Control Valve
Heat Exchanger
High Limit Switch
Igniter
Blower Performance Data—Single Phase
Low
Watts Amps Rise
600
150
0.67
570
140
0.65
510
130
0.63
450
125
0.61
380
120
0.58
---
---
---
---
---
---
---
---
---
Always verify proper operation after servicing.
For further information on the yearly inspection, consult the User
Manual. It is recommended that a qualified servicer inspect and
service the unit at least once each year.
Turn the unit on at the thermostat. Wait a few minutes, since any
dislodged dust will alter the normal flame appearance. Flames
should be predominantly blue and directed into the tubes. They
should not be yellow. They should extend directly outward from
the burner ports without curling downward, floating or lifting off
the ports.
Functional Parts List
Condenser Coil
Condenser Fan Blade
Condenser Fan Motor
Contactor
Gas Manifold
Evaporator Coil
Refer to the description in Functional Parts List when
ordering any of the listed functional parts. Be sure to provide
the unit model and serial numbers with the order.
Although only functional parts are shown, all sheet metal
parts, doors, etc., may be ordered by description.
Parts are available from your distributor.

APPENDIX

Med
CFM
Watts Amps Rise
57
850
230
1.02
60
830
220
1.00
NR
765
215
0.97
NR
715
210
0.94
NR
660
205
0.90
NR
610
195
0.88
NR
---
---
---
NR
---
---
---
CAUTION
Ignition Control
Induced Draft Blower
Pressure Switch
Pressure Switch Hose
Transformer

General Information

High
CFM
Watts Amps Rise
40
1,190
380
41
1,140
360
45
1,080
350
48
1,025
340
52
975
330
56
920
310
NR
830
300
NR
730
290
1.67
NR
1.62
NR
1.58
32
1.54
33
1.38
35
1.37
37
1.35
41
1.32
47