ELECTRICAL REQUIREMENTS
OBSERVE ALL NATIONAL ELECTRICAL CODES AND LOCAL CODES
AND ORDINANCES
ELECTRICAL SERVICE - 120 VOLTS, 60 HZ ONLY
A 120 VOLT, 60 HZ, 15 ampere fused electrical supply is required. An individual branch
(or separate circuit serving only this appliance is recommended).
DO NOT USE EXTEN-
SION CORD unless it meets all requirements as outlined for grounding, polarizing (3-wire)
and capacity. Wire size should be at least No. 14.
BEFORE PLUGGING IN POWER CORD, OPERATING OR TESTING, follow
grounding instructions in Grounding Section.
GROUNDING - 120 VOLTS, 60 HZ
IMPORTANT SAFETY PRECAUTIONS
WARNING - To prevent unnecessary risk of fire, electrical shock or personal injury, all wir-
ing and grounding must be done in accordance with National Electrical Code and local codes
and ordinances.
It is the personal responsibility and obligation of the appliance owner to
provide adequate electrical service for this appliance.
ELECTRICAL GROUND IS REQUIRED ON THIS APPLIANCE
GROUNDING INSTRUCTIONS
This appliance is equipped with a power supply cord having a 3-prong grounding plug. For
your safety, this cord must be plugged into a mating 3-prong type wall receptacle which is
properly wired, grounded, and polarized.
If a mating wall receptacle is not available,
contact a qualified electrician to have the wall receptacle replaced. If there is any question,
local building officials or electrical utility should be consulted.
DO NOT UNDER ANY CIRCUMSTANCES,
REMOVE THE ROUND GROUNDING
PRONG FROM POWER SUPPLY CORD.