Item
Condition
14.DQT
3) Adj item [FDQT
Devition
Adjust [∗∗∗]
Adjust
PTT:ON
[Wide 4K]
E, E4
15.DTMF
1) Adj item [DTMF]
Deviation
Adjust [∗∗∗]
Adjust
LPF:15kHz
[Wide 5K]
HPF:OFF
E, E4
PTT:ON
[Narrow]
(N)E, (N)E4
2) Adj item [DTMF
Adjust [∗∗∗]
PTT:ON
16.TONE
1) Adj item [TONE]
Deviation
Adjust [∗∗∗]
Adjust
LPF:15kHz
[Wide 5K]
HPF:OFF
E, E4
PTT:ON
[Narrow]
(N)E, (N)E4
2) Adj item [TONE
Adjust [∗∗∗]
PTT:ON
17.BATT
1) Adj item [BATT]
Detection
Adjust [∗∗∗]
Writing
PTT:ON
18.BATT
[Panel Test Mode]
Detection
1) CH-Sig:1-1
Check
BATT terminal voltage:6.5V
PTT:ON
2) BATT terminal voltage:5.7V
PTT:ON
TK-360G/(N)/370G/(N)
ADJUSTMENT
Measurement
Test equipment
.
]
Power meter
Dev meter
Oscilloscope
.
]
.
]
Power meter
DVM
Terminal
Parts
ANT
Encoder
SP/MIC connector
knob
ANT
Encoder
BATT
knob
terminal
Adjustment
Specifications/
Remark
Method
±50Hz
Wide 5K:0.75kHz
Narrow:0.35kHz
Wide 4K:0.6kHz
±0.1kHz
Wide 5K:2.5kHz
Narrow:1.25kHz
Wide 4K:2kHz
±0.1kHz
Wide 5K:3.0kHz
Narrow:1.5kHz
Wide 4K:2.4kHz
After pressing the
BATT terminal
PTT switch, confirm
voltage:5.9V
that one predeter-
mined numeric in the
range of 1 to 256
appears and then
press the [2] key.
That number will be
stored in memory.
Check
No blinking of LED
Blinking of LED
43