nest Learning thermostat Installation And Configuration Manual page 9

Thermostat
Hide thumbs Also See for Learning thermostat:
Table of Contents

Advertisement

Nest Learning Thermostat 1st Generation
Nest Learning Thermostat 1st Generation
Nest Learning Thermostat 1st Generation
Nest Learning Thermostat 1st Generation
Conventional connectors
Conventional connectors
Rh
24VAC power from heating transformer*
W1
Stage 1 heat relay
Y1
Stage 1 cooling compressor relay
G
Fan relay
C
24VAC common wire.
O/B
Not used
AUX/W2
Stage 2 heat relay
Rc
24VAC power from cooling transformer*
* No jumper wires required. You don't need to hang on to any old jumper wires going from Rh (sometimes
just called R) to Rc. Nest will automatically jump these two connectors.
Nest Learning Thermostat installation & configuration guide
Heat pump connectors
Heat pump connectors
Rh
24VAC power from heating transformer*
W1
Not usually used
Y1
Stage 1 compressor contact
G
Fan relay
C
24VAC common wire.
O/B
Changeover valve
AUX/
Auxiliary heat relay
W2
Rc
24VAC power from cooling transformer*