Supported wiring

Nest Learning Thermostat 2nd Generation
Nest Learning Thermostat 2nd Generation
Nest Learning Thermostat 2nd Generation
Nest Learning Thermostat 2nd Generation
Conventional connectors
Conventional connectors
Y1
Stage 1 compressor relay
Y2
Stage 2 compressor relay
G
Fan relay
O/B
Not used
Rc
24VAC power from cooling transformer*
W1
Stage 1 heat relay
W2/AUX
Stage 2 heat relay
C
24VAC common wire.
*
Stage 3 heat (W3), humidification (HUM), or
dehumidification (DEHUM)
Rh
24VAC power from heating transformer*
* No jumper wires required. You don't need to hang on to any old jumper wires going from Rh (sometimes
just called R) to Rc. Nest will automatically jump these two connectors.
Nest Learning Thermostat installation & configuration guide
Heat pump connectors
Heat pump connectors
Y1
Stage 1 compressor relay
Y2
Stage 2 compressor relay
G
Fan relay
O/B
Changeover valve relay
Rc
Not used
W1
Stage 1 heat relay
W2/AUX
Auxiliary heat relay
C
24VAC common wire.
*
Emergency heat (E), humidification (HUM), or
dehumidification (DEHUM)
Rh
24VAC power from transformer*