Carrier A07049 Installation Instructions Manual page 47

Performance series programmable/non-programmable control ac / hp thermostat
Table of Contents

Advertisement

Thermostat
RVS/Heat Stage 2
O/B W2
Heat Stage 1
W/W1
Compressor
Y/Y2
Not Used
Y1
Fan
G
24VAC Hot Heating
Rh
24VAC Hot Cooling
Rc
Dry Contact 1
D1
Dry Contact 2
D2
24VAC Common
C
Humidify
HUM
Outdoor Air Temp
OAT
Remote Room Sensor
RRS
OAT/RRS Com
OAT/RRS
Fig. 18 - - Fan Coil shown with Auxiliary Connection #1
* Indicates connection may not be required/available.
Fan Coil
O
W3
W2
G
R
Aux. Connection
COM
Humidifier Solenoid
Valve *
Outdoor Sensor *
Remote Room
Sensor *
47
A07082

Hide quick links: