Carrier A07049 Installation Instructions Manual page 33

Performance series programmable/non-programmable control ac / hp thermostat
Table of Contents

Advertisement

OF (off) — The Humidifier Pad Reminder is disabled and will never be
displayed.
1- -24 — The number of months after which the Humidifier Pad Reminder icon
will be displayed, "CHECK HUM PAD".
Default is OF (off).
Option 30 — Programmable Fan (programmable models only)
This selection allows the homeowner to program the fan selection to "Auto" or
"On" fan operation for each of the program schedule periods. This selection is
only available on programmable models.
OF (off) — Programmable fan is disabled and the homeowner must manually
select "Auto" or "On" for fan operation.
On — Programmable fan is enabled. The homeowner can program "Auto" or
"On" fan operation along with the heat and cool setpoints for each programmed
period. When the program schedule is running, the programmed heat setpoint,
cool setpoint, and fan selection for that period will be used. If the homeowner
"overrides" the programmed fan setting by pressing the fan button, the override
selection will remain in effect until the next programmed period time.
Default is OF (off).
Option 31 — Daylight Savings Time Configuration (programmable models
only)
This selection allows the installer to set the thermostat to automatically change
by one hour on the specified day, month, and week specified.
OF (off) — Daylight Savings Time Function disabled.
1,2 On — The first time the UP/DOWN button is pressed, the value of this
selection changes from OF (off) to 1. When 1 is displayed, the days of the week
and clock digits will be turned on. The installer will set the start date (Spring) for
33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents