If you are using a pulse communications format, a decimal zero [0] does not transmit. Programming a zero [0] tells the panel not to send
any pulses for that digit. Decimal zero [0] is a filler digit. To transmit a zero [0], it must be programmed as a Hexadecimal 'A'.
Example:
For the three digit account number '403', you would enter:
[4], [
[1][
][3], [0]:
,
,
[4] to enter the digit 4
[
] to enter Hexadecimal mode (Ready light flashes)
,
[1] to enter A
[
] to return to decimal mode (Ready light is solid)
,
[3] to enter the digit 3
[0] to enter the digit 0 as a filler digit.

4.4 Programming Toggle Option Selections

Some programming sections contain several toggle options. The panel will use zone lights 1 through 8 to indicate if the different
options are enabled or disabled. Press the number corresponding to the option to turn it ON or OFF. Once all the toggle options have
been selected correctly, press the [#] key to exit the section and save the changes. The Ready light will turn OFF and the Armed light
will turn ON.
Refer to the Programming Worksheets in this manual to determine what each option represents and whether the light should be ON or
OFF for your application.

4.5 Viewing Programming

LED and Fixed Message LCD Keypads
Any programming section can be viewed from an LED keypad. When a programming section is entered, the keypad will immediately
display the first digit of information programmed in that section. The keypad displays the information using a binary format, according
to the following chart.
Press the Fire keys to advance to the next digit. When all the digits in a section have been viewed, the panel will exit the section; the
Ready Light will turn OFF and the Armed light will turn ON, waiting for the next three-digit programming section number to be
entered. Press the [#] key to exit the section.
LCD Keypad
When a programming section is entered, the keypad will immediately display all the information programmed in that section. Use the
arrow keys (< >) to scroll through the data being displayed. Scroll past the end of the data displayed or press the [#] key to exit the sec-
tion.

4.6 DLS Programming

4.6.1 Local Programming with PC-Link
Follow the steps below in the sequence indicated to set up local programming using DLS:
1.
Plug in PC-Link header.
2.
Initiate a DLS PC-Link session on the DLS computer.
3.
When the session is complete, remove the PC-Link cable from the alarm system.
4.
Complete installation.
Note: Connecting the DLS PC to the system automatically initiates the connection.