Trouble Shooting
A) Low Voltage Shut Down
Check Start
Turn AC power off
Disconnect CN805 of Power PCB
Turn on the set after AC power on
N
Y
Is 'SHUT DOWN' occured?
Turn AC power off
Turn AC power off
Connect CN805 back and disconnect
Replace Main B/D
CN 801, CN803, CN804 of Power PCB
Connect all connectors and set Power
Disconnect P6 of Y-SUS B/D
PCB's voltage switch to High
Turn on the set after AC power on
Done
N
Y
Is 'SHUT DOWN' occured?
Turn AC power off
Turn AC power off
Disconnect P2, P3 of Z-SUS
Connect P6 back and disconnect
P1 of Z-SUS B/D
Go to 'Z-SUS, Digital
B/D, Data B/D Shut
Go to 'Y-SUS, Scan B/
Down' part
D Shut Down' part