Dimensions & Capacities; Ice Machine - Cornelius I-SERIES Training Manual

Hide thumbs Also See for I-SERIES:
Table of Contents

Advertisement

I-Series Ice Machine Training Manual
6. Ice builds on the evaporator
to about 1/8" (.32cm) bridge
thickness (center measure,
adjustable). When the hot-gas
defrost valve opens, the water
dump valve opens, and the
pump motor runs for 15 sec-
onds to expel the waste water.
NOTE: The hot-gas defrost
valve opens at approxi-
mately 0° F (-18° C),
and can be adjusted by
turning the ice thick-
ness potentiometer.
7. Ice drops from the evaporator
and opens the curtain proximity switch.
8. After the ice drops into the bin, the curtain proximity switch close. The defrost
stops and the ice making process starts over.
9. If the ice does not drop into the bin because the bin is full, the defrost will con-
tinue for approximately 8 seconds and stop. The ice machine then waits for the ice
to fall into the bin and the curtain and proximity switches to close.
3.2 Dimensions & Capacities

Ice Machine:

Ambient operating temperature:- - - - - - - - - - - - - - - 50-100° F (10-38° C)
Water: - - - - - - - - - - - - - - - - 20-50 psi (1.4-3.45 BAR) at the ice machine.
- - - - - - If the water pressure exceeds 50 p.s.i. install a water pressure regulator
Electrical: - - - - - - - - - - - - - - - - - - - - - - - - - see unit's name plate
- 6 -