Table of Contents
loading

Summary of Contents for Electrolux COOKERS

  • Page 1 SERVICE MANUAL COOKERS Built-in hob Interface Kite 2 © Electrolux Distriparts Publ.-Nr.: Fürther Straße 246 599 714 137 D-90429 Nürnberg Germany DGS-TDS-N Edition: 12.08...
  • Page 2: Table Of Contents

    Five-zone input electronics ....................9 Error Codes induction hobs ....................10 Error Codes for cooking hobs with radiant heating ............10 Failure detection ........................ 11 DGS-TDS-N 12.08 U. H. / A. B. © Electrolux - 2 - 599 714 137 EN...
  • Page 3: Esd=Electrostatic Discharge

    Endangered are all assembly groups which are provided with control entries, wire paths lying open and free-accessible processors. DGS-TDS-N 12.08 U. H. / A. B. © Electrolux - 3 - 599 714 137 EN...
  • Page 4: Overview

    Kite = Slider technology Split = Interface left and right 7-S.D. = 7 Segments to display Bargraph = light chain for displaying power level DGS-TDS-N 12.08 U. H. / A. B. © Electrolux - 4 - 599 714 137 EN...
  • Page 5: Configuration

    Split interfaces for induction hobs Induction coils Kite Split Silicone carrier Split input electronics for hobs with radiant heating Kite Split Silicone carrier Carrier Power electronic DGS-TDS-N 12.08 U. H. / A. B. © Electrolux - 5 - 599 714 137 EN...
  • Page 6: Differentiation Between The Input Electonics Right / Left

    “R” for tight display and “L”. 5-zone input electronics for cooking hobs with radiant heating Kite Split Silicone carrier Carrier HOC 2010 230V Power electronic DGS-TDS-N 12.08 U. H. / A. B. © Electrolux - 6 - 599 714 137 EN...
  • Page 7: Service Menue

    Stored Error Codes With pressing the Plus-Key the last 3 stored Errors are displayed in serial mode If no failure is stored only “E” is diplayed. DGS-TDS-N 12.08 U. H. / A. B. © Electrolux - 7 - 599 714 137 EN...
  • Page 8: Radiant-Heated Cooking Hobs With Split Input Electronics

    Stored Error Codes With pressing the Plus-Key the last 3 stored Errors are displayed in serial mode If no failure is stored only “E” is displayed. DGS-TDS-N 12.08 U. H. / A. B. © Electrolux - 8 - 599 714 137 EN...
  • Page 9: Five-Zone Input Electronics

    Stored Error Codes With pressing the Plus-Key the last 3 stored Errors are displayed in serial mode If no failure is stored only “E” is displayed. DGS-TDS-N 12.08 U. H. / A. B. © Electrolux - 9 - 599 714 137 EN...
  • Page 10: Error Codes Induction Hobs

    2. Check wiring between interface and power board 3. Change induction module Internal interface error Exchange interface with silicone Liquid blocks interface carrier DGS-TDS-N 12.08 U. H. / A. B. © Electrolux - 10 - 599 714 137 EN...
  • Page 11: Failure Detection

    More than one Phase is missing, Check voltage on mains heater is not Connection is not right connection; Check cable working connection in the main terminal DGS-TDS-N 12.08 U. H. / A. B. © Electrolux - 11 - 599 714 137 EN...