Writing And Rewriting The Pld Internal Data - Sony CCU-590 Maintenance Manual

Camera control unit
Hide thumbs Also See for CCU-590:
Table of Contents

Advertisement

3-10. Writing and Rewriting the PLD
Internal Data
This unit uses the PLD (Programmable Logic Device) that
supports the e-Production (EPR) system to write and
rewrite the internal data.
If the part listed below needs to be replaced or to be
upgraded, contact your Sony Sales Office/Service Center.
n
The part number of PLD (or ROM for PLD) in which data
is not written yet, is shown in "Section 1. Spare Parts" of
the MAINTENANCE MANUAL Volume 2.
Therefore, if part replacement is required, write the data by
the following procedure.
In the case of the PLD type that runs on the program stored
in external ROM, data needs not to be written only by
replacing the part if the specific PLD only is defective.
e-Production system has the advantages shown
below.
. To write/rewrite the PLD internal data:
1. The standard fixture (cable) can be used.
2. The standard software (PLD Download Tool) can be
used.
. The PLD internal data is controlled in the Sony Database
Server under the name Project file (E_xxx_xxx_xx_xx).
. The printed circuit board is equipped with the standard
connector (EPR connector) to write the PLD internal
data. The indication "EPR" is shown on the printed
circuit board.
Corresponding PLD
PLD
EPR connector
(Ref No./board name) (Ref No./board name)
IC507/AT-155
CN701/AT-155B
IC106, 502, 708/
CN701/EN-156B
EN-156
IC306, 307/IV-57
CN401/IV-57B
IC105/AU-295
CN100/AU-295
3-18
Equipment required
. PLD download fixture
(Sony part number: J-7120-140-A)
The cable connected PC to this unit.
. PC
A PC having parallel port.
A PC in which the PLD Download Tool software is
already installed.
For the applicable OS and the operating environment,
refer to "Download Tool Operating Instruction for
Device Programming".
Data write procedure
Data write procedure in the PLD (or ROM for PLD) is
outlined below.
For details of data write procedure, refer to "Download
Tool Operating Instruction for Device Programming"
which is available in the same site where the PLD Down-
load Tool software is available.
1. Prepare the Project file.
n
Download the Project file from the Sony Database
Server.
2. Turn off the power of this unit. Connect the PC
parallel port to the EPR connector of the target board
using the PLD download fixture (cable).
3. Turn on the power of this unit.
Start the Download Tool software and read the Project
file.
4. Program the PLD (or ROM for PLD) with the Down-
load Tool software.
Project file No.
5. Upon completion of programming, check that error
message is not displayed. Turn off the power of this
E_000_002_08_xx
unit and back on.
E_000_002_37_xx
E_000_002_38_xx
E_000_002_39_xx
CCU-590/P/V1(E)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ccu-590p

Table of Contents