4-7-5. RX PROMPT VIDEO Level Adjustment

Adjustment category:
B
Note:
Use a TRIAX cable (300 m
maximum) for this adjustment.
The CA-590/590P shall have
been adjusted properly.
Measuring instruments: Waveform monitor, Video
signal generator (10 STEP
signal)
Extended board:
TR-133B board
Preparation:
n
The RX PROMPTER output terminal must be output from
RET-2/PROMPTER BNC on the CCU rear panel.
. S2 (TX ← REM → RX)/TR-133B board (CCU) →
"RX"
. S1 (MODE AUTO/MAN)/DM-140 board (CCU) → "F"
(AUTO)
. Set S301 on the DM-139B board of CA-590/590P to
"TX"
. PROMPT OUT / Rear panel → Disconnect 75 Z
termination.
. Input 10 STEP signal from the video signal generator to
the PROMPTER terminal on the CA-590/590P side
panel.
Adjustment procedure:
. Adjust 1RV902 (PROMPT LEVEL) on the TR-133B
board so that RET-2/PROMPTER video level becomes
1.00 ± 0.03 V p-p.
Note:
Perform the following after the adjustment is completed.
. Set S2 (TX ← REM → RX) on the TR-133B board to
TX side with POWER ON and then to REM.
. Re-set S301 on the DM-139B board of CA-590/590P to
"RX"
. Disconnect the BNC cable from the PROMPTER
terminal.
4-36
1.00 ±0.03 V p-p
CN902
E1
G
F
TP202
RV801
RV201
RV601
E
TP801
LV602
E801
LV901
LV601
LV201
RV901
D
TP201
LV902
C
RV701
RV902
TP901
TP1
TP21
TP41
B
E701
TP701
A
RV41
S1
E101
1
2
TR-133B BOARD (SIDE A)
S2
S363
E300
TP402
TP302
RV401
RV301
TP401
TP301
LV402
LV302
LV401
LV301
E100
TP101
E102
LV101
RV101
3
4
CCU-590/P/V1(E)