Mitsubishi Electric FR-A5AX Instruction Manual page 22

Transistorized inverter
Table of Contents

Advertisement

2) FR-V500 series
Terminal assignment of input signal is determined according to Pr.180 to Pr.183 and Pr.187 (input
terminal function selection).
Signal Name
RL
Low speed operation command
RM
Middle speed operation command
RH
High speed operation command
RL
Remote setting (setting clear)
RM
Remote setting (deceleration)
RH
Remote setting (acceleration)
REX
15-speed selection(combination with RL, RM, RH)
(4) If 0-5V (0-10V) is entered into terminal 1 of the inverter from the external variable resistor with the option
(FR-A5AX) mounted on the inverter, operation is performed at the frequency (speed), which is the sum
of the BCD code input of the FR-A5AX and the auxiliary input from terminal 1, only when 2 or 3 is set
in Pr. 304.
When switching the inputs e.g. between volume input to perform manual operation and BCD code input
to perform automatic operation, set the BCD code input to "0" under manual operation.
REMARKS
When performing an auxiliary input using terminal 1 with the FR-V500 series, set "0" (factory setting) in Pr.868 "Ter-
minal 1 function assignment".
Description
17
PARAMETERS