WARNING
During equalization, the battery generates potentially flammable gases.
Follow all the battery safety precautions listed in this guide. Ventilate the
area around the battery thoroughly and ensure that there are no sources
of flame or sparks in the vicinity
Turn off or disconnect all loads on the battery during equalization. The voltage
applied to the battery during equalization may be above the safe levels for some
loads. Be sure to check battery electrolyte before and after equalization. Fill only
with distilled water.
4.4 Using A Generator as Source Power
Many generators provide output voltage that is modified sine wave (MSW) rather
than the true sine wave (TSW) that your utility provides. TBB does not permit the
use of TRIDENT + with modified sine wave generator due to increased heating of
the charger.
TECHNICAL SPECIFICATION
5.1 Physical Specifications
Dimensions
Weight
Enclosure
Assembly
Fixture
5.2 Electrical Specifications
Number of battery
Explosion hazard
12V12A-2 W PFC
12V12A-2 W/O PFC
12V25A-3 W PFC
12V25A-3 W/O PFC
12V25A-3 W/O PFC
12V12A-2 W PFC
12V12A-2 W/O PFC
12V25A-3 W PFC
12V25A-3 W/O PFC
12V25A-3 W/O PFC
Aluminum with anodized, flame proof plastic
Wall-mounted
Screws
12V12A,24V06A --- 2 isolated
300×190×70mm
300×190×70mm
350×190×70mm
350×190×70mm
350×190×70mm
2.0kg
2.1kg
2.5kg
2.2kg
2.8kg