6.2 TROUBLESHOOTING

Display
Power indicator light is OFF
Power indicator light is flashing
Charged indicator light is flashing,
battery charger has no output
Reverse polarity indicator light ON
Reverse polarity indicator light flashing
Charging and Charged indicator light
flashing
solution of water and baking soda.
Periodically, check all wiring connections, Dc and AC, to be sure
they have not loosened or deteriorated. Also check all cable
clamps to ensure they are tightly fastened.
Condition
Battery charger disconnected
Power supply failure
Incorrect power supply connection
Mains voltage too low
Mains fuse blown
Battery connection not good
Wrong voltage battery connected (24V to
12V battery charger)
The equalization switch (switch 3) is set to
ON before the battery charger is power on.
Please power off the battery charger. Reset
the equalization switch to Off, then power
on the battery charger.
Polarity reversion on output
Charger over temp. charger will reduce the
output power
Battery over temp, charger shut off