REMKO PG 25 Operation Manual
REMKO PG 25 Operation Manual

REMKO PG 25 Operation Manual

Propane heater

Advertisement

Propane – Heater
REMKO PG 25
REMKO PG 50
Operation
Technology

Spare Parts

REMKO – strong as a bear.
Edition GB– L07

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PG 25 and is the answer not in the manual?

Questions and answers

Summary of Contents for REMKO PG 25

  • Page 1: Spare Parts

    Propane – Heater REMKO PG 25 REMKO PG 50 Operation Technology Spare Parts REMKO – strong as a bear. Edition GB– L07...
  • Page 3: Table Of Contents

    Safety hints Block diagram Gas supply Technical data Starting Drawing PG 25 Shut down List of spare parts PG 25 Unit function Drawing PG 50 Interference elimination List of spare parts PG 50 Maintenance Troubleshooting instructions Always keep these operating instructions near or on the device!
  • Page 4: Safety Hints

    Safety hints Gas supply The gas supply/operation of the unit may be carried out Please make sure that the relevant local building only based on the safety regulations VBG 21 as well as and fire protection codes as well as the regulations on the applicable local building and fire protection codes.
  • Page 5 Important Installation Hint Multi - cylinder Set When the gas hose is installed or removed make sure All cylinder valves are to be opened to ensure regular to counteract at the gas connection nipple of the unit gas tapping. (according to DIN 4815, part 2) by means of an open- ended spanner SW 19, whereby the left-handed thread gas hose to unit is to be taken into account.
  • Page 6: Starting

    Starting Setting/Regulation of Heating Capacity Set desired heating capacity at the continuous "Power- A properly trained person is to be charged with the Regulation". operation of the units, as well as with the control of the holders and the cylinder stock. Turn to the left: larger heating capacity The operator's attention is to be drawn to any...
  • Page 7: Unit Function

    Unit function When the unit has been switched on (operating switch in position "I" = heating operation), the supply air fan is started and the electric solenoid opens. However, gas supply to the burner is still blocked. Gas supply to the burner is released only after having pressed on the pin of the thermoelectric gas valve (safety pilot).
  • Page 8: Maintenance

    Maintenance Removal and Cleaning of the Gas Burner Remove blow-off protective grid and outside casing, The units are to be checked by an expert as to their as well as the inspection cover at the lower side of perfect operation, when it is necessary and in accordan- the unit.
  • Page 9: Block Diagram

    A prerequisite for any material guarantee claims is that the orderer or the orderer’s customer filled out a „guarantee certification” at the time of the purchase and start-up and returned it to REMKO GmbH & Co KG. Guarantee certificates are enclosed with every REMKO-heater.
  • Page 10: Drawing

    Drawing PG 25 We reserve the right to make modifications in dimensions and construction in the interests of technical progress.
  • Page 11: List Of Spare Parts

    List of spare parts PG 25 Fig.-No. Description EDV-No. transport handle 1101142 outside casing 1101381 combustion chamber 1101384 end plate, front 1101382 blow out protection grille 1101383 safety thermostat with sensitive element 1101197 inspection cover 1101385 terminal strip, 6er 1101366...
  • Page 12: Drawing

    Drawing PG 50 We reserve the right to make modifications in dimensions and construction in the interests of technical progress.
  • Page 13: List Of Spare Parts

    List of spare parts PG 50 Fig.-No. Description EDV-No. transport handle 1101142 outside casing 1101378 insulation 1101379 combustion chamber 1101422 gas burner 1101423 blow out protection grille 1101424 gas nozzle 1101426 gas pipe Z/D 1101458 angled screw coupling 1/8" x 6 mm 1101316 ignition electrode 1101280...
  • Page 14: Troubleshooting Instructions

    Troubleshooting instructions trouble: cause: – unit doesn’t start 1 – 2 – 3 – 4 – 7 – unit stops during operation 2 – 4 – 7 – 13 – 14 – fan blows, but gas supply is blocked 4 – 5 – 9 – 10 – 13 resp.
  • Page 16 REMKO GmbH & Co. KG Klima- und Wärmetechnik 32791 Lage · Im Seelenkamp 12 32777 Lage · Postfach 1827 Telefon (0 52 32) 606-0 Telefax (0 52 32) 606260...

Table of Contents