REMKO PG-T 25 Operating And Installation Instructions
REMKO PG-T 25 Operating And Installation Instructions

REMKO PG-T 25 Operating And Installation Instructions

Propane gas heating units

Advertisement

Quick Links

Operating and installation instructions
REMKO PG-T (S-Line) Series
Propane gas heating units
PG-T 25, PG-T 25 S-Line, PG-T 50, PG-T 50 S-Line
This product is not suitable as a main heater.
Edition EN - Y04
Read the instructions prior to performing any task!

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PG-T 25 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for REMKO PG-T 25

  • Page 1 Operating and installation instructions REMKO PG-T (S-Line) Series Propane gas heating units PG-T 25, PG-T 25 S-Line, PG-T 50, PG-T 50 S-Line This product is not suitable as a main heater. Edition EN - Y04 Read the instructions prior to performing any task!
  • Page 3: Table Of Contents

    12-13 Troubleshooting 14-16 Electrical wiring diagram PG-T 25 (S-Line) unit representation PG-T 25 (S-Line) spare parts list PG-T 50 (S-Line) unit representation PG-T 50 (S-Line) spare parts list Maintenance protocol Technical data Carefully read this operating manual prior to commissioning/ using the units.
  • Page 4: Safety Notes

    REMKO PG-T (S-Line) SERIES Safety notes Always observe the respective local building code and fire prevention guidelines, as well as the guidelines of the accident prevention and insurance associations, when using the units The units have been subjected The units must be installed and Never insert foreign objects into ■...
  • Page 5: Intended Use

    “Certificate of When disposing of packaging structural design and equipment. guarantee” to REMKO GmbH & material, please consider our According to DIN EN 1596, the Co. KG at the time when the units environment.
  • Page 6: Unit Description

    REMKO PG-T (S-Line) SERIES Unit description The units are mobile fan-assisted Operating sequence A manual reset of the STB can only air heaters (WLE) directly fired be implemented after the units with liquid gas, without a heat Moving the operating switch have cooled down.
  • Page 7: Installation Instructions

    Installation instructions CAUTION The safety regulations of the The fresh air supply required ■ for trouble-free combustion accident prevention and insurance For use in public buildings, must be ensured. It is practical associations, the respective national regulations must be to have the fresh air supply regional building regulations observed.
  • Page 8: Gas Connection

    REMKO PG-T (S-Line) SERIES Gas connection The gas connection/unit operation All common gas cylinder sizes ■ CAUTION must take place exclusively on the are permitted for the gas Before all work on the gas basis of the accident prevention supply. However, a gas cylinder supply and when replacing gas regulation DGUV 79, “Use...
  • Page 9 Connecting the gas supply Assembly note Icing up of gas cylinders 1. Connect the With insufficiently dimensioned During the assembly or disassembly pressure controller of the gas hose, it is necessary gas supply systems, there is a risk to the gas cylinder to counter-hold the unit by the of the pressurised gas cylinder or gas supply...
  • Page 10: Commissioning

    REMKO PG-T (S-Line) SERIES Commissioning Tank gas systems The units should be checked for Connecting the units to the visible defects on the operating electrical power supply When connecting the units to tank and safety devices as well as gas systems, ensure sufficient pipe proper installation and correct 1.
  • Page 11 Heating without room Setting and controlling the Heating with room thermostat thermostat heating capacity (Accessories) The units operate in continuous The desired or required heating The units operate fully operation without room capacity can be steplessly set on automatically and according to the temperature regulation.
  • Page 12: Shutdown

    REMKO PG-T (S-Line) SERIES Shutdown Care and maintenance Ventilation 1. Close the shut off valve(s) of the NOTE gas supply system and allow the Regular care and maintenance, In this operating mode, the supply gas flame to burn out. at the latest after every air fan runs permanently.
  • Page 13 VDE 0701 after any work objects! on the units. Unit type 11. Carefully remove deposits or PG-T 25 approx. 3 mm approx. 15 mm soiling in the unit base. PG-T 50 approx. 3 mm approx. 15 mm 12. After all cleaning work on the...
  • Page 14: Troubleshooting

    REMKO PG-T (S-Line) SERIES Troubleshooting Malfunctions: Cause: Unit does not start. 1 – 2 – 3 – 4 – 5 – 7 – 10 – 13 – 17 – 18 Unit switches off during operation. 2 – 6 – 7 – 8 – 9 – 10 – 13 – 14 – 17...
  • Page 15 Automatic firing device - LME41 The unlock key is the central The multicoloured signal lamp in During commissioning, indication control for unlocking, as well as the unlock key is the central display takes place in accordance with the activation / deactivation of the element for visual and interface following table: diagnostics.
  • Page 16 REMKO PG-T (S-Line) SERIES Troubleshooting diagnostics After an unchangeable fault Pressing the unlock key again >3 >3 seconds switches this off again. shutdown, the red signal lamp seconds activates the interface The correct switching moment is lights up. In this condition, it is diagnostics.
  • Page 17: Electrical Wiring Diagram

    Electrical wiring diagram PG-T 25 (S-Line)/PG-T 50 (S-Line) 11 12 31 32 PGT 30/60-R07 Legend: = Ionisation electrode = Terminal block = Fan motor = Solenoid valve = Relay socket = Thermostat socket = Operating switch STB = Safety temperature limiter...
  • Page 18: Pg-T 25 (S-Line) Unit Representation

    REMKO PG-T (S-Line) SERIES PG-T 25 (S-Line) unit representation 2, 2a We reserve the right to modify the dimensions and design as part of the ongoing technical development process.
  • Page 19: Pg-T 25 (S-Line) Spare Parts List

    PG-T 25 (S-Line) spare parts list No. Description EDP no. No. Description EDP no. 1 Transport handle 1101142 27 Adjusting knob, cpl. 1101192 2 PG-T 25 exterior cladding 1121184 28 Strapping plug 1101019 2a PG-T 25 exterior cladding 1101073 29 Thermostat socket...
  • Page 20: Pg-T 50 (S-Line) Unit Representation

    REMKO PG-T (S-Line) SERIES PG-T 50 (S-Line) unit representation 2, 2a We reserve the right to modify the dimensions and design as part of the ongoing technical development process.
  • Page 21: Pg-T 50 (S-Line) Spare Parts List

    PG-T 50 (S-Line) spare parts list No. Description EDP no. No. Description EDP no. 1 Transport handle 1101142 32 Thermostat socket 1101018 2 PG-T 50 exterior cladding 1101420 33 Strapping plug 1101019 2a PG-T 50 (S-Line) exterior cladding 34 Gas connection nipple 1101134 On request 3 Insulation...
  • Page 22: Maintenance Protocol

    REMKO PG-T (S-Line) SERIES ✍ Maintenance protocol Unit type: ........Unit number: ........10 11 12 13 14 15 16 17 18 19 20 Unit cleaned - outside - Unit cleaned - inside - Fan blade cleaned Combustion chamber cleaned...
  • Page 23: Technical Data

    Technical data Series PG-T 25 (S-Line) PG-T 50 (S-Line) Nominal heat load max 26.00 55.00 Nominal heat capacity 26.00 55.00 Minimum heat capacity 10.00 25.00 Air flow volume 1310 Fuel Fuel/gas type Cat I Energy efficiency ratio Unit connection pressure...