Technical Data Gas Supply Troubleshooting Starting Exploded View PG 25 T / 25 TE Unit Shut Down Spare Part List PG 25 T / 25 TE Safety Mechanism Maintenance Log Maintenance Always keep these operating instructions near or on the unit!
Safety Instructions Description of the Unit Make sure to observe relevant local building and fire The unit is directly fired with liquid gas in a gaseous protection codes and abide by professional association state. The unit works without an exhaust connection regulations when the unit is in operation.
General Instructions The unit may only be operated by persons who have Prior to operating the unit, the operating personnel received proper training in its operation and how to must check that the unit and its safety mechanisms handle liquid gas. are functioning properly and that the safety mecha- nisms have not been removed.
Gas Supply Important Safety Instructions Connect the gas hose as follows: The gas tanks may not be placed directly behind the unit! 1. Connect the pressure controller to the gas cylinder(s). Never heat up or de-ice the gas tank using the hot air coming out of the unit.
Starting Automatic heating with room thermostat When operating units, the respective and relevant local The unit runs automatically with the temperature which guidelines must be observed. has been pre-selected on the room thermostat. You must also observe these additional instructions: 1.
Unit Shut Down Maintenance 1. Close all cylinder valves. Depending on the operating conditions, the units must be serviced as necessary, at least once every two years 2. Let the flame burn out. by a authorised individual to ensure that they are func- tioning properly.
“guarantee certificate” enclosed with 4. Loosen the ignition cable on the ignition electrode. all heating units and send it back to REMKO GmbH & 5. Loosen the cable on the ionisation electrode. Co. KG in a timely manner after purchasing of the unit Pay attention to the union nut and the spring ring.
RT = room-thermostat plug socket S = switch STB = safety temperature limiter Z = ignition electrode ZT = ignition transformer Technical Data Series PG 25 T / 25 TE Rated heat output Heating capacity 10 - 25 Air output m³/h Fuel/type of gas Liquid gas Cat.
Spare Part List PG 25 T / 25 TE Description Ref. No. transport handle 1101142 outside casing PG 25 T 1101475 outside casing PG 25 TE (INOX) 1101476 combustion chamber 1101384 end plate, front 1101382 blow-out protection grille 1101383 safety temperature limiter with sensor...