4.2. Drive I/O Objects
4.2.1. Binary Input Object Instance
The output terminals and the input terminals can be monitored.
Binary Input
Instance ID
Binary input #0
Binary input #1
Binary input #2
Binary input #3
Binary input #4
Binary input #5
Binary input #6
Binary input #7
4.2.2. Binary Input Object Instance
The output terminals can be controlled via network. Set the terminal function parameter before control
via network.
Binary Output
Instance ID
Binary Output #0
4.2.3. Analog Output Object Instance
The analog input value can be monitored.
Analog Input
Instance ID
Analog Input #1
Object Name
VFFS1
RO 1 ACT
FL
RO 2 ACT
RY
---
---
---
---
---
---
---
---
DI 1 ACT
F
DI 2 ACT
R
Object Name
VFFS1
RO 1 CMD
FL
Object Name
VFFS1
ANALOG INPUT 2
VIB
- 13 -
Description
Output terminal monitor
Output terminal monitor
Reserve
Reserve
Reserve
Reserve
Input terminal monitor
Input terminal monitor
Description
Output terminal function
Set f132 to 38.
Description
Analog input monitor
E6581404
Active /
Access
Inactive
ON / OFF
R
ON / OFF
R
---
---
---
---
---
---
---
---
ON / OFF
R
ON / OFF
R
Active /
Access
Inactive
ON / OFF
C
Units
Access
%
R