B
AG I
LACKHEAT
NSTALLATION
SECTION 4: MAJOR COMPONENT DESCRIPTIONS
Burner (shown with Tube
Gasket)
Must be installed with the
flame observation window
facing down.
Burner Tube
Supplied in 3000 mm lengths.
Burner tube is always the first
tube after the burner.
Tube and Reflector Hanger
with Clamp Package
Position this hanger no more
than 100 mm away from the
burner assembly.
Tube and Reflector Hanger
Suspend system from these
hangers.
Reflector Support Strap, Wire
Form & #8 x 3/4 Screw
8
O
S
M
PERATION AND
ERVICE
Tube
Heat treated aluminised tube
supplied in 3000 mm lengths.
Flex Gas Line
Tee
Assembly
ANUAL
Reflector
(Aluminium or
Stainless Steel)
Alternate overlap as
shown on overview.
Minimum overlap is 160 mm.
Bow
Shackle
Fan Tube with Internal Swirler
Supplied in 3000 mm lengths. Fan
tube is always the last tube on the
heater where the fan is attached.
The swirler is welded inside of the
tube end.
Coupling Assembly
with Lock
Reflector End Cap
Punch out center section to
accommodate tube.
Fan Assembly (Includes Flange)
Fan assembly is attached to the last
section of tubing (fan tube).
Damper Flange Assembly
For use on Multiburner Systems.
Fan Flange Assembly
and Screws
Height
Adjuster
Spring
Hook
S-hook