Fixtures must be installed by a Qualified electrician in accordance with all
national and local electrical and construction codes and regulation.
4.1 Connection to the mains
For protection from electric shock, the fixture must be earthed!
The Robin DLS is equipped with auto-switching power supply that automatically adjusts to any 50-60Hz AC
power source from 00-40 Volts.
Install a suitable plug on the power cord if needed, note that the cores in the power cord are coloured according
to the following table. The earth has to be connected!
If you have any doubts about proper installation, consult a qualified electrician.
Core (EU)
Brown
Light blue
Yellow/Green
4. Installation
Core (US)
Connection
Black
Live
White
Neutral
Green
Earth
6
Plug Terminal Marking
L
N