Robin 300E Spot User Manual

Spot wireless dmx crmx

Advertisement

Quick Links

Version1.6


Advertisement

Table of Contents
loading

Summary of Contents for Robin 300E Spot

  • Page 1 Version1.6...
  • Page 2: Table Of Contents

    Robin 300E Spot Table of contents 1. Safety instructions ......................3 2. Operating determination ....................4 3. Fixture exterior view ...................... 5 4. Installation........................6 4. Connection to the mains .................... 6 4. Installing the lamp ...................... 7 4.3 Lamp adjustment ....................... 7 4.4 Replacing the colour filters and gobos ..............
  • Page 3: Safety Instructions

    CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing! FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOU INITIAL START - UP! 1. Safety instructions Every person involved with installation and maintenance of this device have to: - be qualified - follow the instructions of this manual CAUTION!
  • Page 4: Operating Determination

    2. Operating determination This device is a moving head for creating decorative effects and was designed for indoor use only. If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising condensation water might damage your device. Leave the device switched off until it has reached room temperature.
  • Page 5: Fixture Exterior View

    3. Fixture exterior view 1 - Front lens 2 - Tilt lock 3 - Pan lock 4 - Base 5 - Moving head 6 - Arm The head should be locked for transportation- the tilt lock latch (2) and the pan lock latch (3) have to be in the locked positions.
  • Page 6: Installation

    4.1 Connection to the mains For protection from electric shock, the fixture must be earthed! The Robin 300ESpot is equipped with auto-switching power supply that automatically adjusts to any 50/60Hz AC power source from 100-240 Volts. For use with 100-120 V supplies, both main 5 A fuses has to be exchanged for 8 A fuses which are enclosed in the packing.
  • Page 7: Installing The Lamp

    4.2 Installing the lamp DANGER ! Install the lamp with the device switched off only. Unplug from mains before ! To insert the new lamp. 1. Disconnect the fixture from power and allow it to cool at least 5 minutes. 2.
  • Page 8: Replacing The Colour Filters And Gobos

    4.4 Replacing the colour filters and gobos DANGER! Install the colour filters or gobos with the device switched off only. Unplug from mains before! Colour filters 1. Disconnect the fixture from mains and allow it to cool. 2. Remove the top plastic cover of the head by loosening the 4 quarter-turn fasteners on the cover. 3.
  • Page 9 Rotating gobos 1. Disconnect the fixture from mains and allow it to cool. 2. Remove the bottom plastic cover of the head by loosening the 4 quarter-turn fasteners on the cover. 3. Gently pull up the gobo holder from the rotation gobo wheel. 4.
  • Page 10: Rigging The Fixture

    4.5 Rigging the fixture The installation of the fixture has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation. The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net. This secondary safety attachment must be constructed in a way that no part of the installation can fall down if the main attachment fails.
  • Page 11 Truss installation 1.Bolt each clamp (1) to the omega holder (3) with M12 bolt and lock nut through the hole in the holder. 2.Fasten the omega holders on the bottom of the base by inserting both quick-lock fasteners (4) into the holes of the base and tighten fully clockwise.
  • Page 12 4.6 DMX-512 connection The fixture is equipped with both 3-pin and 5-pin XLR sockets for DMX input and output.The sockets are wired in parallel. Only use a shielded twisted-pair cable designed for RS-485 and 3-pin or 5-pin XLR-plugs and connectors in order to connect the controller with the fixture or one fixture with another.
  • Page 13: Ethernet Connection

    The Universe is a single DMX 512 frame of 512 channels. The Robin 300ESpot is equipped with 8-pin RJ- 45 socket for Ethernet input.Use a network cable category 5 (with four “twisted” wire pairs) and standard RJ-45 plugs in order to connect the fixture to the network.
  • Page 14 Ethernet / DMX operation Options “Art2DMX” has to be selected from the “Ethernet Mode” menu on the first fixture (connected to the Ethernet) in the fixture chain,next fixtures have standard DMX setting. Connect the Ethernet-input of the first fixture in the data chain with the network. Connect the DMX output of this fixture with the input of the next fixture until all fixtures are connected to the DMX chain.
  • Page 15: Remotely Controllable Functions

    For this reason, you have to wait 5 minutes after having switched the lamp off before you can switch it on again. If you try to switch on the lamp within 5 minutes after having switched it off, the Robin 300ESpot will store this information and automatically ignite the lamp when the 5 minutes period has expired.
  • Page 16: Control Menu Map

    6. Control menu map Default settings=Bold print Level 1 Level 2 Level 3 Level 4 Level 5 Level 6 Addressing Settings DMX Address 00-55 Ethernet Settings Ethernet Mode Disable ArtNet gMAI gMA2 Art2DMX IP Address/Net Mask Default IP Address Custom IP Address Net Mask ArtNet Universe 0-55...
  • Page 17 Level 1 Level 2 Level 3 Level 4 Level 5 Level 6 Ambient Temperatures Base Temperatures Personality User Mode User A Settings User B Settings User C Settings Mode 1 DMX Presets Mode  Mode 3 View Selected Preset Off, On Pan/Tilt Settings Pan Reverse Off, On...
  • Page 18 Level 1 Level 2 Level 3 Level 4 Level 5 Level 6 Stand -Alone Test Sequences Dynamic Mode Static Mode 0-55 Tilt 0-55 Zoom 0-55 Focus 0-55 HotSpot 0-55 MusicTrigger Off, On Preset Playback None Test Prg. 1 Prg. 2 Prg.
  • Page 19: Control Menu

    7. Control menu The Robin 300ESpot Light is equipped with the QVGA Robe touch screen with battery backup which allows to set the fixture´s behaviour according to your needs, obtain information on its operation, test its vari- ous parts and lastly program it, if it has to be used in a stand-alone mode.
  • Page 20: Tab " Address

    Touch any part of the screen or press the [ENTER/Display On] button to display the initial screen with the cur- rent stored DMX address: Touch the green arrow at the bottom right corner of the screen or press the [ENTER/Display On] button to enter the "...
  • Page 21: Tab "Information

    Resetable Hours - The item shows the number of the operation hours with the lamp on that the Robin 300ESpot has been powered on since the counter was last reset. In order to reset this counter to 0, touch the text box next to the item "Resetable Hours:"...
  • Page 22: Tab "Personality

    7.3 Tab "Personality" User mode - The Robin 300ESpot allows you to recall up to 3 user settings. After switching the fixture on for the first time, the User A settings is active. Now all changes made in the “Personality” menu , ”Addressing”...
  • Page 23 User B Settings - the function recalls the user B settings. User C Settings - the function recalls the user C settings. DMX Preset - Use the menu to select desired channel mode. Mode 1 - 3 control channels Mode 2 - 5 control channels Mode 3 - 3 control channels View Selected Preset - Use the menu to display channels included in the selected mode.
  • Page 24: Tab "Manual Control

    Play Program 2 - The option starts user program No. . Play Program 3 - The option starts user program No. 3. Edit Program - Use the menu to create or to edit desired program. The Robin 300ESpot offers 3 free programs,...
  • Page 25: Tab "Service

    each up to 00 steps. Edit Program 1 - The option allows to edit user program No.1. Edit Program 2 - The option allows to edit user program No.2. Edit Program 3 - The option allows to edit user program No.3 To edit program: 1.
  • Page 26 Magenta - magenta flags Zoom - a zoom module Yellow - yellow flags Focus - a focus module CTO - CTO flags HotSpot- a fine movement of reflector Static Gobo - a static gobo wheel Dimmer 1 - a dimmer lamella  Rot.
  • Page 27: Icon "Lamp Menu

    DMX512, the RDM protocol allows a console or dedicated RDM controller to send commands to and receive messages from specific moving lights. RDM allows explicit commands to be sent to a device and responses to be received from it. The list of commands for Robin 300ESpot is the following. Parameter ID Discovery command SET command...
  • Page 28: Wireless Dmx Operation

    ...Commands relative resetable values 9. Wireless DMX operation The wireless version of the Robin 300E Spot is equipped with the Lumen Radio CRMX module and antenna for receiving DMX signal. CRMX module operates on the 2.4 GHz band. To link the fixture with DMX transmitter.
  • Page 29 List of error and information messages: Active Lamp Timer This message appears if you try to switch on the lamp within 5 minutes after having switched it off. The fixture will store the attempt to ignite the lamp and automatically ignites the lamp when the 5 minutes period will expire. Lamp Error If the ignition of the lamp is 4 times unsuccessful (the “Active Lamp Timer”...
  • Page 30: Technical Specifications

    Focus Error 1 (Focus Error 2 ) The messages will appear after the reset of the focus module if the focus lens is not located in the default. Gobo Carousel Error 1 (Gobo Carousel Error 2 ) The messages will appear after the reset of the rotating gobo wheel if this wheel is not located in the default position.
  • Page 31 Prism Rotating 3-facet 11° prism with continuous rotation in both directions Iris Motorized iris for different beam diameters Frost filter Separate,variable frost filter Zoom Linear motorized zoom: Strobe Strobe effect with variable speed (max.15 flashes/sec.) Electronic strobbing (max. 33 flashes/sec.) Dimmer Smooth dimmer from 0 - 100 % Control...
  • Page 32: Maintenance And Cleaning

    Minimum distances Min. distance from flammable surfaces: 1 m Min. distance to lighted object: 2 m Total heat dissipation 1426 BTU/h (calculated) Weight (net) 0 kg Dimensions (mm) Accessories - Omega holder (No.99010420)........2 pcs - Gobo-set 16 (No.15050025)........1 pcs Optional Accessories - Flash cable RS232/DMX (No.13050624) 12.
  • Page 33 " # & '() ! " & " & & !"#$"## % !& ' # . /0 # . /0 # . /0 . /0 & & ( # . /0 . /0 && &&( - # . /0 & &...
  • Page 34 && ;< & & ( =0 &1 &1, &1 & & + & 1 3 & &+1 6 &+ &,& 2 $0 &, & & : & & ( ;< &( & &+ &, > & 1 - #/ ! ( ) ! "' &...
  • Page 35 &,+ & 1 & &(& &( &(( & &+ 1& ( ) ! "' . C D ) +,) - 5 AE5 3 " !&1$ & & &1 &( & & & & & & ( 6 && &&( 6 &...
  • Page 36 &( &(( 6 & 3 & / ! $ 1 > 1 - #/ ! $ ( ) ! & " / / # !&34 !" !# !$ & && & & &+ &( 1& !" !# !$ & 1+ 1( &...
  • Page 37 1 > 1 - #/ ! $ ( ) ! "' " + / # & !' !( !) & !' !# !) > & & , / ! $ & & ( > &1 - #/ ! $ " + / # &...
  • Page 38 & &(& 5 &( &( ( ) ! $ " & ) ! $ " 1 ) ! $ " $ " & & & 6 & 1& !4 2 !. ! & (+ & , '0. !. ! & &...