IBM System Storage DCS3700 Installation, User's, And Maintenance Manual page 155

Hide thumbs Also See for System Storage DCS3700:
Table of Contents

Advertisement

One or more green
Power supplies
LEDs are off
Several components Hardware failure
Front panel
All drives
One or more green
All drives
LEDs are off
(continued)
(continued)
Power cable is
disconnected or switches
are turned off
The DCS3700 was not
powered-on, or all SAS
cable connections
between the storage
enclosures and the
DCS3700 storage
subsystem failed.
Power supply problem
Hardware failure
Midplane failure
The DCS3700 expansion
enclosure is connected to
unsupported storage
subsystem
The DCS3700 storage
system is connected to
unsupported expansion
enclosure
Bad disk drawer
The disk drawer cable
chains are not installed
correctly
Drives are not fully
inserted in the drive
drawers
On activity to the drives
Damaged or loose SAS
cables
ESM failure. Use the
Storage Manager software
to check the drive status,
if necessary, replace the
ESM.
Make sure that the power cables are
connected (ac or dc) and that the
disconnect device (dc only) and the
power-supply switches are turned on.
Replace the affected components. If this
does not correct the problem, replace the
controllers. Contact your IBM
technical-support representative.
Perform one of the following actions:
v Power-on the storage subsystem.
v Make sure that the SAS cable
connections between the storage
enclosures and the DCS3700 storage
subsystem are made.
Make sure that the power cables are
connected and that the power supplies are
turned on.
If any other LEDs are lit, replace the
midplane. Contact your IBM
technical-support representative.
Replace the DCS3700. Contact your IBM
technical-support representative.
Verify that the expansion enclosure is
connected to a supported storage
subsystem. See http://www.ibm.com/
systems/storage/disk
Verify that the storage system is connected
to a supported expansion enclosure. See
http://www.ibm.com/systems/storage/
disk
Use Storage Manager software to verify
the drive drawer failure and replace the
drawer.
This condition might occur after the disk
drawer is replaced and the disk drawer
cable chains are not fully inserted in the
disk drawer or the midplane sockets. Use
the instructions in "Replacing a drive
drawer" to reseat the left and right disk
drawer cable chains.
Verify that the drives are seated correctly
in the drive drawers. Remove and reinsert
the drives if required.
No action is required.
Check the SAS cables and connections.
Use the Storage Manager software to
check the drive status, if necessary, replace
the ESM.
Chapter 6. Hardware maintenance
133

Advertisement

Table of Contents
loading

Table of Contents