Download Print this page

Makita JV100DZ Technical Information page 3

Cordless

Advertisement

R
epair
[3] DISASSEMBLY/ASSEMBLY
[3] -1. Housing
DISASSEMBLING
Fig. 2
1. Remove Clamp plate and Base from
Housing set by unscrewing M4x16
Hex socket head bolt with Hex wrench 3.
Base
Clamp plate
3. Remove Safety wire.
ASSEMBLING
(1) Make sure to insert Holder to Housing L (Fig. 3).
Fig. 3
(2) Set Safety wire to Housing L (Fig. 2-3).
(3) Assemble Housing R to Housing L (Fig. 2-2).
(4) Assemble Base and Clamp plate to Housing set and tighten them with M4x16 Hex socket head bolt (Fig. 2-1).
M4x16 Hex socket
head bolt
Hex wrench 3
(Standard equipment)
Note;
Before assembling Housing R, make sure that Holder
(with M4 Screw hole) is mounted to Housing L
to fasten Housing set with M4x16 Hex socket head bolt
2. Separate Housing R by unscrewing M4x35
Tapping screw (1pc.) and 4x18 Tapping screws (9pcs).
4x35 Tapping screw (1 pc.)
4x18 Tapping screw (9 pc.)
Housing R
Safety wire
Holder
P 3/ 11