SEQUENCE OF OPERATION

Turn on the unit by pressing and releasing the POWER
button. The backlit POWER and RESET button will
illuminate along with the first green LED indicating power
is present. When the indoor fan is operating the first
green LED will slowly flash. This indicates the FIELD
CHARGER and COLLECTION CELLS have power and
the unit is operating normally. There is a slight time
delay between the indoor fan starting and LED flashing.
NOTE: There is a 10 [12] minute delay after the indoor
fan operates, before the air cleaner starts to operate,
each time the power to the air cleaner is turned off/on.
Your air filtration system only operates when the air is
circulating through the indoor unit. The air filtration
system is most effective at cleaning the air if the fan
operates continuously. Most thermostats have a
setting that will permit continuous fan operation.
Continuous fan mode during Cooling operation
may not be appropriate in humid climates. If the
indoor air exceeds 60% relative humidity or simply
feels uncomfortably humid, it is recommended that
the fan only be used in the AUTO mode.
In normal operation, the air cleaner may make a slight
sound as the air passes through it and is cleaned. In
some applications, you may notice this sound coming
from the return air vent(s). If desired, this sound level
can be reduced with minimal impact on air cleaning
efficiency by reducing the power setting of the FIELD
CHARGER in the SET-UP mode (see pages 7-8).

MAINTENANCE

WARNING
!
RISK OF ELECTRIC SHOCK: These servicing
instructions are for use by qualified personnel
only. To reduce the risk of electric shock, do not
perform any servicing other than that contained in
this User's Information Guide unless you are
qualified to do so.
CAUTION
!
Before cleaning the coil or ducts in the air handler or
furnace, remove the COLLECTION CELLS, FIELD
CHARGER, and PRE-FILTER from the air cleaner.
Chemicals used during the cleaning of the air
handler, furnace, or ductwork can damage the air
cleaner components and degrade the performance of
the air cleaner.
32-5038-06
Numbers in [brackets] are for 50 Hz international systems.
User's Information
For maximum efficiency, the COLLECTION CELLS and
PRE-FILTER should be inspected and cleaned as
prescribed in this User's Information Guide.
The FIELD CHARGER should only be removed and
cleaned annually by a qualified service professional.
CLEANING
Cleaning Instructions:
The air cleaner utilizes a PRE-FILTER and
COLLECTION CELLS. The purpose of the PRE-FILTER
is to capture large particles before they enter the
COLLECTION CELLS which allows the COLLECTION
CELLS to work more efficiently.
1.
Turn the air conditioning system off at the Comfort
Control (thermostat).
WARNING
!
High Voltage is present within the air cleaner for
operation. Before removing the Power Door, turn the
power off and wait at least 15 seconds to allow
voltage to discharge. Failure to follow instructions
could result in death or serious personal injury.
2. Turn off power to the air cleaner by pushing and
holding the POWER button for three seconds. The
LED's will remain on until the voltage has discharged
and it is safe to remove the door. This requires
approximately 15 seconds. Do not remove the
door until all the lights are off.
3. Disconnect the power/control cable.
4. Rotate the two latches and remove the door as
shown in Figure 3. Place the door in a secure
location.
CAUTION
!
Handle the door only by using the handles on the
front of the door. Grasp the door by the handles as
depicted in Figure 3 to remove and replace the door.
Do not handle the door on the edges. Metal edges
may be sharp and could result in injury if the door is
not handled properly.
Rotate Latches
Fig. 3