Installer’s Guide A. DUCT SUPPORT INSTALLATION Rafter or Joist ▲ ▲ CAUTION Supply Return SAFETY HAZARD Furnace or Plenum Plenum Air Handler Cleaner Sharp Edge Hazard. Be careful of sharp edges on equip- ment or any cuts made on sheet metal while installing or Return Air Plenum must be servicing.
Installer’s Guide Select a location that meets the following: 4. Install the air cleaner such that the airflow direction arrow on the cabinet always points towards the fur- 1. The face of the cell must be at a right angle to the air stream.
Installer’s Guide Step 2: Rotate the door to fully remove from the air Step 4: Rotate latches to secure door as shown in Figure 15. cleaner. See Figure 11. Rotate door away from unit to remove Rotate door away from unit to remove Air Cleaner Figure 15 Door Latch Detail Figure 11 Door Rotation...
Installer’s Guide DOWNFLOW FURNACE INSTALLATION UPFLOW AIR HANDLER APPLICATIONS ONLY NOTE: On 90% Downflow Furnaces, the intake and 9. Position the baffle onto the air cleaner as indicated in exhaust (flue) are located on top. A field supplied Figure 17. The baffle should be positioned on the transition is needed between the furnace and the air leaving air side of the air cleaner cabinet opposite the power door.
Installer’s Guide 3. On a protective pad, lay the indoor unit on its side. 4. Apply transitions or spacer as required to clear flue piping and to ensure the opening of the air cleaner Position the furnace with the return air side of the cabinet facing up.
• Plug the air cleaner power/control cable into the air cleaner door and route the cable into the indoor unit OTE: A 50 VA transformer is required for Trane/ low voltage wiring location. American Standard Heating & Air Conditioning •...
Page 9
Installer’s Guide ELECTRICAL CONNECTIONS TO A COMMUNICATING SYSTEMS AIR HANDLER ▲ Replace the Communicating control box cover. WARNING Locate the white wire coming from the HAZARDOUS VOLTAGE! DISCONNECT ALL ELECTRIC Communicating System Air Handler PCB labeled POWER, INCLUDING REMOTE DISCONNECTS BEFORE “EAC”.
Page 10
Installer’s Guide ELECTRICAL CONNECTIONS TO A COMMUNICATING SYSTEMS 3-STAGE FURNACE On a downflow furnace, mount the 35 VA transformer on the ▲ WARNING blower deck by drilling two 0.144 inch diameter (#27) holes 13/16" inches apart and attaching the transformer to the HAZARDOUS VOLTAGE! DISCONNECT ALL ELECTRIC blower deck using the screws retained from step 3 above.
Page 11
Installer’s Guide ELECTRICAL CONNECTIONS TO A COMMUNICATING 80% FURNACE ▲ Attach the blue wire from the air cleaner wiring harness to the WARNING open tab on the piggyback terminal supplied in the BAYACCECOMM101. Attach piggyback terminal to the 35VA HAZARDOUS VOLTAGE! DISCONNECT ALL ELECTRIC transformer terminal “C”...
Installer’s Guide ELECTRICAL CONNECTIONS TO AN OIL FURNACE Refer to the diagrams below for proper connections ▲ WARNING to an oil furnace. Consult the oil furnace installer's HAZARDOUS VOLTAGE! DISCONNECT ALL ELECTRIC guide for additional information. POWER, INCLUDING REMOTE DISCONNECTS BEFORE SERVICING.
Installer’s Guide F. AIR CLEANER OPERATION G. SET-UP MODE A combination of RED, YELLOW, and GREEN LED's are LED's used to indicate the following settings. See Figure 25. • The three GREEN LED's are used to indicate PRE- CLEAN FILTER cleaning interval. This is measured in actual run POWER time of the indoor fan.
Installer’s Guide CELL CLEANING SETTING (Figure 27) H. MAINTENANCE One or more of the YELLOW LED’s will come on indicating the COLLECTION CELL cleaning time setting. ▲ Repeatedly press the RESET button to cycle through the CAUTION time options for the COLLECTION CELL cleaning cycle until the desired setting is displayed.
Page 15
Installer’s Guide 5. Remove the PRE-FILTER (Figure 30) and/or the The air cleaner is factory set to notify the home owner to COLLECTION CELLS (Figure 31) from the air cleaner. clean the PRE-FILTER every two months [10 weeks] of actual run time of the air cleaner. This notification can be changed by the installer/home owner to 1 month [5 weeks] or 3 months [15 weeks] depending on the conditions in the home (pets, smokers, etc.).
Page 16
Installer’s Guide 1. Using a vacuum hose, vacuum in even strokes across the entire COLLECTION CELL surface. Vacuum using even strokes in one direction, then repeat the process using even strokes in the opposite direction, as demonstrated in Figure 34. Handles Fold Flat Figure 36 Collection Cell, Handle Folded...
Page 17
Installer’s Guide Alternate Cleaning option for homeowners with 200 • Do NOT use soap or detergent in cleaning the COL- or 200-1 COLLECTION CELLS ONLY LECTION CELLS. Vacuuming the PRE-FILTER and COLLECTION CELLS • Do NOT immerse the COLLECTION CELLS com- restores them to a high efficiency.
Page 18
Installer’s Guide 5. Replace the door onto the air cleaner cabinet (see NOTE: The pre-filter may also be washed ONLY if Reinstalling the Power Door, page 5). the COLLECTION CELLS show a "200/200-1". Follow the same instructions to wash the PRE- FILTER - being sure to tap gently and wipe off any visible water droplets.
Installer’s Guide I. OUTLINE DRAWINGS Dimensions (all dimensions in inches) OUTLINE DRAWING FOR UPFLOW FURNACES 27” DEPTH CABINET ADD DOOR DEPTH FOR TOTAL 2.8” Side View 7-7/16 24-13/16 Front Cabinet UPFLOW FURNACE MODEL NUMBERS ifD Air Cleaner B (multiple B (one piece piece cabinet) cabinet) *FD145ALFR000C...
Page 20
Installer’s Guide Dimensions (all dimensions in inches) OUTLINE DRAWING FOR DOWNFLOW FURNACES 21” CABINET DEPTH ADD DOOR DEPTH FOR TOTAL 2.8” Side View 7-7/16 18-13/16 Front Cabinet DOWNFLOW FURNACE MODEL NUMBERS B (multiple B (one piece ifD Air Cleaner piece cabinet) cabinet) *FD14DALFR000C 14.5...
Page 21
18.88 Front Cabinet AIR HANDLER MODEL NUMBERS B (multiple B (one piece ifD Air Cleaner piece cabinet) cabinet) *FD215ALAH000C 21.5 18.9 TFD215ALAH005C *FD235ALAH000C 23.5 20.9 TFD235ALAH005C *FD260ALAH000C 26.0 23.4 23.5 TFD260ALAH005C * May be "A" or "T" Pub. No. 18-HE53D1-7...
Page 23
Installer’s Guide Pub. No. 18-HE53D1-7 Numbers in [brackets] are for 50 Hz international systems.
Page 24