Siemens VIS3I-328 Installation Manual page 51

Integrated system unit
Table of Contents

Advertisement

VisiPC Settings
Test Type
Test Level
Cards
All cards
Video input switch with C
telemetry
D telemetry card
VIS3I-328 video output
Alarm input
Relay output
Communications
Quad option card
Telemetry Cards
Internal loopback
External loopback
Video Routing
Unused
Loopback type
Plug
RS-232 Male
9-pin male D
RS-232 Female
9-pin female D
RS-422
9-pin male D
RS-232 TTL
96-pin DIN41612
Siemens Building Technologies
Fire Safety & Security Products
Hardware
Required
None
None
None
None
None
None
None
None
None
Loopback connectors fitted
to all D-type ports
One or more external
sources of video connected
to camera inputs
VIS3I-328 – VisiPC self-tests
Tab. 38
Serial port external loopback connectors
The self-test external loopback tests confirm that the serial ports are working
correctly. To conduct this test you need to fit special test plug connectors to each
of the serial ports. The test connectors are wired to feed back the transmitted
output as a receiver input. Tab. 39 identifies the wiring requirements for each of the
test plug connectors.
Pins linked on
connector
2-3
2-3
4-5
A15-C15
Serial port loopback test connectors (1)
Tab. 39
To fully test the serial ports that are wired for both RS-232 and RS-422, you need
two separate external loopback tests that use different loopback connectors, as
shown in Tab. 40.
Precautions
See Tab. 41
Video sources must
be good quality such
as direct camera video
Pins linked on
Number
connector
required on
Master unit
4
4-6-1-9 ,7-8
1
8-9
4
A16-C16
1
Description
Tests all the
following internal
card types
Tests internal
loopback
Tests internal
loopback
Tests card presence
Tests card presence
Tests card presence
Tests internal serial
ports used for future
option cards
Test Quad card (if
fitted)
Tests all D-type and
C-type ports using
internal loopback
switching
Tests all D-type port
connections via
external loopback
connectors
Tests video routing
from connected
cameras to internal
monitor outputs
Number
required on
Slave unit
3
1
3
1
51
10.2008

Advertisement

Table of Contents
loading

This manual is also suitable for:

Visilynx 3

Table of Contents