Load New Configuration As Necessary; Load Asian Display Font Data - Siemens VIS3I-328 Installation Manual

Integrated system unit
Table of Contents

Advertisement

8.7

Load new configuration as necessary

Parameter
Settings
Camera Inputs
64
Monitor Outputs
16
Comms Channels
21
Internal Quads
4
Telemetry Cards
4
Video Loss Alarms
64
External Alarm Inputs
256
Serial Port 1
Communication Channel 1 set to Network Control Input
PCCON Serial Port 2
Communication Channel 2 set to PCCON2/3 Remote Control
Serial Port 3
Communication Channel 3 set to Data Log
Serial Port 4
Communication Channel 4 set to Debug
Test / Config Serial Port 9
Communication Channel 9 set to V3 Remote Control
Keyboard Serial Port 10
Communication Channel 10 set to Keyboard Input
8.8

Load Asian display font data

Siemens Building Technologies
Fire Safety & Security Products
Each installation requires its own unique configuration for it to operate correctly
with the cameras and monitors in use. You edit and load this configuration using
the VisiPC (Visilynx 3 Configurator) sub-program.
Each VIS3I-328 is supplied with a factory default configuration pre-loaded during
manufacture. You restore this default configuration using the VisiPC (Visilynx 3
Configurator) sub-program and selecting New on the File menu, and then
transferring it to the VIS3I-328. You can also use this configuration file as a basis
for editing a new configuration tailored to the installation.
Some of the pre-loaded configuration settings are shown in Tab. 6.
Factory default matrix configuration
Tab. 6
For further instructions on loading and editing configuration files, refer to the VisiPC
Operations Manual.
If you are using the VIS3I-328 units in an Asian country, you may need to install
the combined European and Asian display font data using VisiPC, as only the
European display font data is installed during manufacture.
Do not attempt to load the Asian font if the PC running VisiPC software is
loaded with the Chinese version of the Windows operating system. Due to
IMPORTANT
incompatibilities outside Siemens' control, this may fail. Instead, use a PC
loaded with European or American Windows.
To transfer the Asian font to a VIS3I-328 unit:
1.
Run the VisiPC software with the PC COM port connected to the Test/Config
port.
2.
Select the VisiPC (Visilynx 3 Configurator) sub-program, as detailed in the
VisiPC Software User Manual.
3.
On the menu bar select Transfer, then the Software option and then Ok.
4.
Select the SW251-2.x.hex file from the CD and press the Open button.
NOTE
This takes several minutes to transfer to the unit.
Notes
1 – 4 and 9 – 10 on master rear panel, 16-19
on slave rear panel (other channels not used)
To enable internal option cards
64 D-type channels (C-type disabled by
default)
Alarm numbers 1 – 64
Alarm numbers 513 – 768
9600 Baud, 8 data bits, no parity, 1 stop bit
9600 Baud, 8 data bits, even parity, 1 stop bit
9600 Baud, 8 data bits, no parity, 1 stop bit
9600 Baud, 8 data bits, no parity, 1 stop bit
38400 Baud, 8 data bits, no parity, 1 stop bit
9600 Baud, 8 data bits, even parity, 1 stop bit