8.3

Set VisiPC default product to integrated

8.4

Connect and power up the VIS3I-328s

24
Siemens Building Technologies
Fire Safety & Security Products
PC COM Port 25-Way 'D' Female
2
3
7
Cable wiring for 25-way PC COM port
Tab. 5
A Baud rate of 38400 is required for communication between the PC and the
Test/Config Connector port on the VIS3I-328. You select the communication Baud
rate using the VisiPC software, as detailed in the User Manual.
1.
Run the VisiPC software.
2.
If VisiPC starts as the Visilynx 3 Tester and Simulator, select the Visilynx3
Configurator sub-program at the Switch drop-down menu, as detailed in the
VisiPC Software User Manual.
3.
From the Options drop down menu highlight Default Product and select
Integrated.
NOTE
This ensures that factory set default data applicable to VIS3I-328 is always loaded when the New
option is selected at the File drop-down menu.
1.
If you want to connect two VIS3I-328s as a single expanded matrix node, you
need to connect an expansion cable (Type VIS3I-EXP) between the
expansion connectors on each rear panel. You should set the Master – Slave
switch on the rear panel of each unit, as required.
2.
Connect each VIS3I-328 to the AC mains supply (see chapter 3.1
Specifications for the allowed mains voltage range).
3.
Switch on the mains power supply to the VIS3I-328. For an expanded matrix
node, switch on both VIS3I-328s simultaneously. If this is not possible, switch
on the Slave VIS3I-328 first.
VIS3I-328 Test/Config Connector 9-Way 'D' Male
3
2
5
10.2008