Configuring Network Alarms - Siemens VIS3I-328 Installation Manual

Integrated system unit
Table of Contents

Advertisement

9.6.4

Configuring network alarms

Siemens Building Technologies
Fire Safety & Security Products
Screen
Parameter
Communication Settings,
Function
Channel 1
Protocol
Node Settings
Name
Remote Prefix
Node Trunk Settings,
Neighbour Node End,
Node trunk 1
Node
Neighbour Node End,
Trunk
Local Node End,
Direction
Local Node End,
Monitor
Example changes to default configuration for Remote Node 2 (5) unit
Tab. 24
The steps required to configure a remote node to broadcast its alarms over the
network are listed in Tab. 26.
Screen
Global System Settings
Alarm Settings, to enable each
alarm to be broadcast to other
nodes
Alarm Keyboard Access
Settings, to enable each alarm
to be broadcast to other nodes
Keyboard Settings, for the local
node keyboard with this
number to be given access to
the alarm(s)
Configuring network alarms on a remote VIS3I-328 node
Tab. 25
The steps required to configure a local node's keyboard(s) to accept alarms from
other nodes over the network are listed in Tab. 26.
Screen
Global System Settings
Keyboard Settings, for the
keyboard(s) that responds to
the remote alarms
Keyboard Alarm Access
Settings, for the keyboard(s)
that responds to the remote
alarms
Keyboard Alarm Node Access
Settings, for the keyboard(s)
that responds to the remote
alarms
Configuring network alarms on a local VIS3I-328 node
Tab. 26
Parameter
Value
Nodes
Total nodes on network (no node must have
its address switch set to higher than this
value)
Exists
Ticked
Type
Camera
Camera
0
Netcast
Ticked
Any keyboard (does
Ticked
not require a
corresponding
keyboard to be
connected)
Alarm Monitors
At least one alarm monitor must be non-blank
(does not require a corresponding monitor to
be connected)
Parameter
Value
Nodes
Total nodes on network (no node must have
its address switch set to higher than this
value)
Alarm Monitors
At least one alarm monitor must be non-blank
(does not require a corresponding monitor to
be connected)
Alarm number(s) to
Ticked
be handled
Node(s) that originate
Ticked
the remote alarms
Value
Network control input
VisiWire
N3
2
1
2
Output
8
10.2008
39