4. NOTE: The thermostat housing bolts are tightened in sequence with the intake manifold bolts. Do not tighten the thermostat housing bolts during thermostat installation.
Install the water thermostat. For additional information, refer to
5. Tighten the 11 bolts in two stages in the sequence shown.
Stage 1: Tighten to 2 Nm (18 lb-in).
Stage 2: Tighten to 25 Nm (18 lb-ft).
6. Connect the two radio ignition interference capacitor electrical connectors.