Connect Electrical Supply; Ventilation Molding; Removing Appliance - Gaggenau VL 414 110 Installation Instructions Manual

Downdraft ventilation
Table of Contents

Advertisement

Available languages

Available languages

6
Insert the control cable from the control unit in
the socket on the appliance. Plug together the
supply cables of the control unit and of the
remote fan unit. The plugs must engage. Connect
the control unit to the mains and check that it is
working. If the appliance is not working, check
that the connecting cables are fitted correctly.
7
Flush installation only: it is imperative to test
functioning before jointing!
gap with a suitable, temperature-resistant silicone
adhesive (such as OTTOSEAL
the seal joint with smoothing agent recommended
by the manufacturer. Observe the notes on
processing the silicone adhesive. Do not operate
the appliance until the silicone adhesive has dried
completely (at least 24 hours, depending on room
temperature).
NOTICE:
Unsuitable silicone adhesive used on
natural stone worktops will cause permanent
discoloration.

Connect Electrical Supply

Refer to data plate for more information. See "Service"
for data plate location.
The branch-circuit breakers ampacity, the wire sizes
and the connections must be conform to the
requirements of the National Electrical Code or
Canadian Electrical Code and all local codes and
ordinances.
Attach flexible conduit to the junction box. Connect
the lead wires to the junction box supply wires in
proper phase:
black (L1) to black
red (L2) to red
green to ground
Joint the surrounding
S 70). Smoothen
®
The mains connecting cable must at least correspond
to the type SJTO 3x16 AWG 105°C. The mains
connecting cable must only be purchased through and
connected by an authorised specialist.
Connection with a plug
Plug has to be conform with NEMA
CONFIGURATIONS FOR PLUGS AND
RECEPTACLES.
The appliance must be properly grounded.
Plug must be rated not less than type 6-20 P (2-
pole 3-wire grounding).
Only a qualified electrician should connect the
plug.
Install a socket outlet earthed in accordance with
regulations approx. 27" (700 mm) above the floor
behind the appliance. The socket outlet must still
be accessible after installation.

Ventilation molding

If downdraft ventilation is used next to a gas
appliance, a ventilation molding AA 414 010 must be
fitted on the gas appliance during cooking. The
ventilation molding improves extraction when using
gas appliances. The ventilation molding prevents
extinction of small flames due to the draft.
AA 414 010
Ventilation molding, for operation next
to the VG 414/415/424/425 gas
appliance

Removing appliance

Disconnect the appliance from the power supply. For
flush-mounted appliances, remove the silicone joint.
Push out the appliance from below.
9
CAUTION
Damage to appliance! Don't lever device out
from above at the frame.