Additional switching output

Work must only be carried out on the additional
switching output by a qualified electrician in
accordance with the country-specific requirements and
standards.
The appliance has an additional switching output X16
(potential-free contact) that can be used to connect
other appliances, such as a ventilation system that is
available at the installation site. The contact is closed
when the fan is switched on, and is opened when the
fan is switched off.
The switching output is located under a cover. Maximum
switching power 30 V/1 A (AC/DC). The signal that is
connected to the contact must correspond to class of
protection 3.

Networked operation

Several appliances can be networked together. The
light and fan on each of the appliances are operated
synchronously.
Connect the appliances in series via the connector
sockets X1 and X2 (equal value). The sequence of the
networking does not have any effect. If the enclosed
network cables are too short, use a commercially
available network cable (min. Cat. 5, shielded).
Maximum number of networked appliances: 20. Total
length of all of the network cables: 40 m. During the
initial installation, a qualified electrician must check
that the system functions correctly.
If one of the networked appliances fails (power
interruption, network cable disconnected), this leads to
the fan function being blocked for the entire system. All
of the buttons on the appliance flash.
When changing the configuration, the system must be
re-initialized:
1
Unscrew the cover plate.
2
Press and hold the reset button until both LEDs
light up continuously (approx. 5 seconds). Then
release the button within 5 seconds.
3
Screw on the cover plate.
18
4
After initialization, have a qualified electrician
check that the system functions correctly.

Connect Electrical Supply

9
WARNING
Risk of electric shock
Parts inside the appliance can have sharp edges.
The connection cable can be damaged. Do not
bend or pinch connection cables during
installation.
Refer to data plate for more information. See "Service"
for data plate location.
The branch-circuit breakers ampacity, the wire sizes and
the connections must be conform to the requirements of
the National Electrical Code or Canadian Electrical
Code and all local codes and ordinances.
This appliance is connected with a plug
Plug has to be conform with NEMA
CONFIGURATIONS FOR PLUGS AND
RECEPTACLES.
The appliance must be properly grounded.
Plug must be rated not less than type 6-20 P (2-pole
3-wire grounding).
Only a qualified electrician should connect the
plug.
Install a socket outlet earthed in accordance with
regulations approx. 27" (700 mm) above the floor
behind the appliance. The socket outlet must still
be accessible after installation.