  • Page 1 All manuals and user guides at all-guides.com Operating and assembly instructions AH 590-720 Freely Suspended Insular Hood...
  • Page 2 All manuals and user guides at all-guides.com AH 590-720 Page 13-19 6. Assembly instructions 6.1 Technical data Page 13 6.2 Installation Page 14-19...
  • Page 3: Technical Data

    All manuals and user guides at all-guides.com 6. Assembly instructions 6.1 Technical data Weight without support frame and LK: 35 kg Weight with support frame and LK: max. 60 kg Dimensions: 47 ´ ´ x 27 ´ ´ / 1198 x 700 mm Electrical connection Pay attention to the rating plate data.
  • Page 4: Installation

    All manuals and user guides at all-guides.com 6.2 Installation The applicable regulations of the energy supply companies and the regional construction regula- WARNING - TO REDUCE THE RISK OF FIRE, tions must be observed when installing the hood. ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: The minimum distance from the worktop to the bottom edge of the wall hood is for electrical appli-...
  • Page 5 All manuals and user guides at all-guides.com Flexible aluminium pipes, corrosion-protected As standard, the blow-out opening of the extractor sheet metal pipes and exhaust air pipes whose hood is in the upward direction. material conforms to fire B1 in accordance with To pass exhaust air through the outer wall, we DIN 4102 can be used.
  • Page 6 All manuals and user guides at all-guides.com Installation above gas cooker / gas hob Installation of the appliance above a gas cooking device must conform to national safety regulations. A minimum distance of 30 ´ ´ / 762 mm between the hood and gas appliance must be observed.
  • Page 7 All manuals and user guides at all-guides.com Note: ") 200 the extractor hood is to be installed to a kitchen ceiling or suspended ceiling. Ensure that the ") 346 ceiling is capable of providing a firm hold for a maximum weight of hood and accessories of 60 kg. Before marking the securing holes, make sure that no electricity wires or water pipes or other wires/ pipes are laid at the drilling points in the ceiling.
  • Page 8 All manuals and user guides at all-guides.com 6. Adjust the support frame to the desired height and secure with 8 screws. The length of the support frame can be adjusted in steps of ´ ´ / 20 mm from 15 ´...
  • Page 9 All manuals and user guides at all-guides.com 11. Adjust the hood to the final position and attach it with all 4 screws to the ceiling (Fig. 23). 12. Connect the air outlet pipe. 13. Connect the hood to the electricity supply. 14.
  • Page 10 All manuals and user guides at all-guides.com GAGGENAU HAUSGERÄTE GMBH 5551 McFADDEN AVENUE P.O. BOX 10 02 50 · D - 80076 MÜNCHEN HUNTINGTON BEACH, CA 92649 GERMANY Y (0 89) 45 90-01 Y (800) 828-9165 · FAX (714) 901-0979 FAX (0 89) 45 90-23 47 www.gaggenau.com/us...