Yamaha EF4500iSE Theory & Diagnostics Manual page 70

Generator
Hide thumbs Also See for EF4500iSE:
Table of Contents

Advertisement

Yamaha Generator Theory & Diagnostics Guide
3. Charging voltage
• Start the engine.
• 3,800 r/min (no load)
• Measure the charging voltage.
Tester positive lead →
Tester negative lead →
È EF3000iSE
É EF3000iSEB
Charging voltage:
12 ~ 16 V
Refer to Service Data Section for Specification
4. Charging coil resistance
• Disconnect the charging coil connector.
• Connect the pocket tester (Ω × 1) to the
charging coil.
Tester positive lead → White terminal 1
Tester negative lead → Ground 2
Charging coil resistance:
White-Ground:
Refer to Service Data Section for Specification
0.35 Ω ± 20% at 20 °C (68 °F)
*
C0NTINUITY
positive terminal 1
negative terminal 2
OUT OF
SPECIFICATION
GOOD
*
CHARGING SYSTEM
È
1
É
1
MEETS SPECIFICATION
Properly connect the charging system.
SWL4130J
OUT OF SPECIFICATION
Replace the charging coil.
2-36
4-16
ELEC
+
2
SWL4120J
2
SWL4120
1
2