AIR SHUTTER ADjUSTMENT (NATURAL GAS ONLY)
ADjUSTING THE AIR SHUTTER
The venturi of the burner is equipped with an air shutter. The opening of the venturi has been set at
1/4" for Natural Gas and fully open for Propane installation at sea level. Natural Gas Models may be
adjusted for high altitude as follows:
•
To increase air mixture, push up the adjustment rod located beneath the stove. This opens the
shutter more and will stop or minimize sooting. Figure 46
•
To decrease air mixture, pull down the adjustment rod located beneath the stove. This closes the
shutter. Flames will be more yellow. Figure 47
203000245
Figure 46 -
Push Adjustment Rod Up to
Open Air Shutter
ST1114
air shutter closed
ST1115
Figure 47 -
Pull Adjustment Rod Down to Close Air Shutter
ST1115
air shutter open
Air Shutter
Adjustment Rod
Air Shutter
Adjustment
Rod
VS38 Direct Vent Gas Stove
ST1114
31