VS38 Direct Vent Gas Stove
Level
Cut Hole 1/8"
Larger than
Support Box
when Projected
onto Roofline.
Figure 21 -
Cathedral Ceiling Support Box Installation
ST1108
VERTICAL TERMINATION CONFIGURA-
cat clg support box
TIONS
Figures 23 through 26 show four different configurations
for vertical termination.
IMPORTANT: You must install a restrictor on all vertical
installations.
NOTE: Install restrictor into 4" collar of stove or first vent
section as shown.
Table 5 - Vertical Venting with Two (2) 90° Elbows
Vertical (V) Minimum
8'
9'
10'
11'
23'
Figure 23 -
Vertical Rigid Venting Configuration Using Two
90° Elbows
18
Cathedral Ceiling
Support Box
2" Minimum Below
Finished Ceiling
ST1108
Horizontal (H) Maximum
2'
4'
6'
8'
8'
ST1109
Figure 22 -
Installed Cathedral Ceiling Support Box
ST1109
installed support box
 
H  
V
ST1110
vert term no 1 elbow
VENTING INSTALLATION
Apply Non-hardening
Mastic Under all Edges of
Support Box before Nailing
NOTE: Install restrictor
into 4" collar of stove
or first vent secton as
shown.
ST1110
203000245