Power Level Setting; Powerboost Function; Control Lock Function - Lincat IH21 User And Installation Instructions Manual

Twin zone induction hob
Table of Contents

Advertisement

LOW TEMPERATURE HOLD
The pan base temperature is monitored through the ceramic glass hobtop, allowing dishes to be kept
warm. The "u" symbol is displayed.
The food type, pan construction material and flatness of the pan base will have a significant effect on
the temperature of the pan contents. To comply with food minimum safe holding temperatures, pan lids
should be fitted and a temperature probe used frequently.
POWER LEVEL SETTING 1 – 9:
There are 9 power level settings available via the rotary control knob
The table below gives the percentage of maximum power for each level setting, also the time limit (in
minutes) for operation at that power.
Power level
Low temp hold
% of Power
Time limit (mins)
POWER BOOST FUNCTION
The IH21 is rated at 3kW total power input.
Normal operation; the large rear coil is rated at 2kw, the small front coil is rated at 1kw (total 3 kW).
If the large rear coil is power boosted, its power increases to 3kW, the front coil will be shut down.
If the small front coil is power boosted, its power increases to 1.8kW, the rear coil is limited to 1.2kW.
Power boost is activated by turning the control clockwise from the level 9 position.
Note: Only one coil can be boosted at a time.
The power boost will run for a maximum of 10 minutes, after that time the zone reverts to level 9. It may
be boosted again providing the system internal temperatures are satisfactory.
AUTOMATIC HEAT-UP CONTROL (AHC):
This is an advanced function.
When activated, the AHC will give maximum power (level 9) to a coil for a preset time before reducing
to a lower power level set by the control.
The table below gives the preset time for each level setting (in seconds) according to the power level.

Power level setting

Preset time (secs)
To activate; the control is turned anticlockwise from the 'off' position briefly whilst the "A" symbol
illuminates; the control is then turned clockwise to set the 'final' required power (1-8). The display will
revert to the "A" symbol and the induction hob will run at maximum power for the time shown in the
table above, before reducing power to the 'final' setting.

CONTROL LOCK FUNCTION

This function prevents unwanted operation of the induction hob, when the control lock is active; the "L"
symbol is displayed.
It is activated and de-activated by turning either control knob anticlockwise to the control-lock position
and held for approximately 6 seconds.
IS429:ECN3369
1
2
---
3%
5%
120
520
402
1
2
3
40
72
120
3
4
5
6
8%
12%
18%
28%
318
260
212
170
4
5
176
256
432
7
8
9
42%
64%
100%
139
113
90
6
7
8
120
192

Hide quick links: