Charcoal Filters; To Remove/Replace Charcoal Filter; Changing The Light Bulb - John Lewis JLBIHD601 Instruction Manual

Built-in cooker hood
Table of Contents

Advertisement

Charcoal Filters

In the recirculation mode the charcoal filters absorb
smells and unwanted odours.
The charcoal filters cannot be cleaned, we recommend
they should be replaced approximately every three
months or more often if the hood is used for more
than three hours per day.
To Remove/Replace the Char-
coal Filters
1. First remove the metal grease filters.
2. Rotate the charcoal filter anti-clockwise (A) and re-
move.
3. To replace the charcoal filters, remove the metal grease
filters.
4. Place the filter over the inlet grille at either end of the
fan housing and rotate clockwise (B) into position.
This appliance can be a possible fire hazard if
the grease and charcoal filters are not cleaned
and replaced as recommended.

Changing the Light Bulb

1. Remove the screw fastening the lamp cover.
2. Pull the lamp cover downwards.
3. Rotate the light bulb anti-clockwise to unscrew.
4. To replace the light bulb insert a replacement into the
holder then rotate the bulb clockwise into position. Ensure
you take care not to overtighten the bulb.
5. Replace the lamp cover.
If the light bulb fails to function check that the bulb is fully
screwed into the holder. If bulb failure has occurred then
it should be replaced with a 220-240 Volt 40W clear globe
shaped bulb with a small E14 screw thread.
Replacement filters and light bulbs can be ob-
tained from your local Service Force Centre.
B
A
12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jlbihd902

Table of Contents