Indoor Unit Installation

1.

Installing the mounting plate

• The mounting plate should be installed on a wall which can support the weight of the indoor unit.
1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark the boring
points on the wall.
2) Secure the mounting plate to the wall with screws.
Recommended mounting plate retention spots and dimensions
Use tape measure
as shown.
Position the end
of a tape measure
at
.
Through the wall
hole φ65mm
Drain hose position
2.

Boring a wall hole and installing wall embedded pipe

• For walls containing metal frame or metal board, be sure to use a wall
embedded pipe and wall cover in the feed-through hole to prevent possible
heat, electrical shock, or fire.
• Be sure to caulk the gaps around the pipes with caulking material to prevent
water leakage.
1) Bore a feed-through hole of 65mm in the wall so it has a down slope toward
the outside.
2) Insert a wall pipe into the hole.
3) Insert a wall cover into wall pipe.
4) After completing refrigerant piping, wiring, and drain piping, caulk pipe hole
gap with putty.
3.
Inter-unit wiring
1) Open the front panel, then remove the service lid.
2) Pass the inter-unit wire from the outdoor unit through the feed-
through wall hole and then through the back of the indoor unit. Pull
them through the front side. Bend the ends of tie wires upward for
easier work in advance. (If the inter-unit wire ends are to be stripped
first, bundle wire ends with adhesive tape.)
3) Press the bottom frame of the indoor unit with both hands to set it on
the mounting plate hooks. Make sure the wires do not catch on the
edge of the indoor unit.
■English
Recommended mounting
plate retention spots.
(5 spots in all)
115
φ65
61
149
278.5
* The removed pipe port cover can be
kept in the mounting plate pocket.
Place a leveler on raised tab.
450
400
Bilt size: M10
Bilt size: M10
Liquid pipe end
Gas pipe end
50
Keep here the piece cut out
from the unit for piping.
800
Removed pipe
port cover
A
Mounting plate
When stripping the
ends of inter-unit wire
in advance, bind right
ends of wires with
insulating tape.
103
200
φ65
175.5
60.5
unit: mm
Inside
Outside
Wall embedded pipe
(field supply)
Caulking
Wall hole cover
(field supply)
Wall embedded pipe
(field supply)
Hang indoor unit's hook here.
Inter-unit wire
A
Mounting plate
8