Functional overview
Electrical data (hot-plug power supply unit)
Rated voltage range
Frequency
Max. rated current
Effective power
Apparent power
Heat dissipation
Main power fuse
Protection class
Power supply configuration note
Power supply efficiency
Electrical value notes
Ambient conditions
Environment class 3K2
Environment class 2K2
Temperature:
Operation (3K2)
Transport (2K2)
Humidity
Condensation during operation must be avoided!
14
100 - 240 V
50 Hz - 60 Hz
8 A
1400 W
1445 VA
5040.0 kJ/h (4777.0 BTU/H)
16 A
I
max. 2 PSU.
92% (at 50% PSU load, CSCI "gold")
Active power max. value depends on
system configuration.
For details see "Power Configuration
Tool".
EN 60721 / IEC 721 Part 3-3
EN 60721 / IEC 721 Part 3-2
5°C ~ 35°C
-25 °C ~ +60 °C
10% ~ 85% (non condensing)
Operating Manual
CX400 S2