Kenwood TK-361SA Service Manual page 24

Kenwood tk-361sa uhf fm transceiver service manual
Table of Contents

Advertisement

TK-361SA
Item
Condition
9. DQT Fine
1) Test CH: Low, Center, High
Deviation
(3 points)
Deviation meter fi lter
LPF: 3kHz
HPF: OFF
PTT: ON
Receiver Section
Item
Condition
1. BPF wave
1) Center frequency
adjust
Spectrum analyzer setting
Center frequency: 460MHz
Span: 200MHz
RBW: 100kHz
VBW: 10kHz
ATT: 5dB
2) High-edge frequency
Sepctrum analyzer setting
Center frequency: 470MHz
3) Low-edge frequency
Sepctrum analyzer setting
Center frequency: 450MHz
2. Sensitivity
1) Test CH: Low, Center, High
SSG output: –116dBm (0.35µV)
SSG MOD: 1.5kHz
3. Squelch
1) Test CH: Low, Center, High
(Open)
SSG output: –122dBm (0.18µV)
SSG MOD: 1.5kHz
4. Squelch
1) Test CH: Low, Center, High
(Tight)
SSG output: –116dBm (0.35µV)
SSG MOD: 1.5kHz
5. Battery
1) BATT terminal voltage: 5.9V
Warning
Level
REF -50.0 dBm
5dB/
A_Write Norm B_Blank Norm
CENTER
460.0 MHz
CENTER 460.0 MHz
∗RBW 100 kHz ∗VBW 10 kHz
∗SWP 400 ms ATT 5 dB
24
ADJUSTMENT
Measurement
Test-
Unit
equipment
Power
TX-RX
meter
Deviation
meter
Oscillo-
scope
AG
AF VTVM
Measurement
Test-
Unit
equipment
Spectrum
TX-RX
analyzer
SSG
DVM
Oscillo-
scope
AF VTVM
DVM
TX-RX
REF -50.0 dBm
5dB/
A_Write Norm B_Blank Norm
CENTER
470.0 MHz
SPAN 200.0 MHz
CENTER 470.0 MHz
∗RBW 100 kHz ∗VBW 10 kHz ∗SWP 400 ms ATT 5 dB
Adjustment
Terminal
Unit
Parts
ANT
Program-
0.40kHz
ming
software:
KPG-88D
(M2)
Adjustment
Terminal
Unit
Parts
ANT
Program-
Adjust the wave-
BPF
ming
form as shown to
software:
the below.
KPG-88D
(M2)
ANT
Check
SP/MIC
Program-
Write
ming
software:
KPG-88D
(M2)
ANT
Write
BATT
terminal
SPAN 200.0 MHz
Specifi cations / Remarks
Method
±40Hz
Specifi cations / Remarks
Method
12dB SINAD or more
Squelch open
BATT terminal voltage: 5.9V
REF -50.0 dBm
5dB/
A_Write Norm B_Blank Norm
CENTER
450.0 MHz
CENTER 450.0 MHz
SPAN 200.0 MHz
∗RBW 100 kHz ∗VBW 10 kHz ∗SWP 400 ms ATT 5 dB