Configuring Drive Parameters
Intelligent Output Terminals – The SJ100DN DeviceNet Series inverters have 5 of the
6 possible output option assignments for standard SJ100 inverters ([OD] is removed).
However, note that the alarm relay contact terminals [AL0], [AL1], and [AL2] are not
present on the SJ100DN DeviceNet Series inverters (so C_24 and C_33 are not present
on SJ100DN).
Func.
Name
Code
C_21 Terminal [11] function
C_22 Terminal [12] function
The output logic convention is programmable for terminals [11] and [12]. The open-
collector output terminals [11] and [12] default to normally open (active low), but you
can select normally closed (active high) for these terminals in order to invert the sense of
the logic.
Func.
Name
Code
C_31 Terminal [11] active
state
C_32 Terminal [12] active
state
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
"C" Function
Description
Select function for terminal
[11],
5 options (see inverter manual
Select function for terminal
[12],
5 options (see inverter manual)
"C" Function
Description
Select logic convention, two
option codes:
00... normally open [NO]
01... normally closed [NC]
Select logic convention, two
option codes:
00... normally open [NO]
01... normally closed [NC]
Defaults
Run
Mode
–FE
–FU
–F
Edit
(CE)
(UL)
(Jpn)
00
00
00
[RUN]
[RUN]
[RUN]
05
05
05
[AL]
[AL]
[AL]
Defaults
Run
Mode
–FE
–FU
–F
Edit
(CE)
(UL)
(Jpn)
00
00
00
00
00
00
Units
Units