28
Configuring Drive Parameters
"C" Group: Intelligent Terminal Functions
Intelligent Input Terminals – The three intelligent input terminals for SJ100DN
DeviceNet Series inverters have 22 possible option assignments.
Func.
Name
Code
C_01 Terminal [1] function
C_02 Terminal [2] function
C_03 Terminal [3] function
NOTE: Terminal [3] can operate as the PTC (thermistor thermal protection) input. Thus,
it has the additional [PTC] terminal input (option code 19) that may be assigned.
The input logic convention is programmable for each of the three inputs. The inputs
default to normally open (active high), but you can select normally closed (active low) in
order to invert the sense of the logic.
Func.
Name
Code
C_11 Terminal [1] active state Select logic convention, two
C_12 Terminal [2] active state Select logic convention, two
C_13 Terminal [3] active state Select logic convention, two
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
"C" Function
Description
Select function for terminal [1]
22 options (see inverter
manual)
Select function for terminal [2]
22 options (see inverter
manual)
Select function for terminal [3]
23 options (see inverter manual
and Note below)
"C" Function
Description
option codes:
00... normally open [NO]
01... normally closed [NC]
option codes:
00... normally open [NO]
01... normally closed [NC]
option codes:
00... normally open [NO]
01... normally closed [NC]
Defaults
Run
Mode
–FE
–FU
–F
Edit
(CE)
(UL)
(Jpn)
00
00
00
[FW]
[FW]
[FW]
21
21
21
[STP]
[STP]
[STP]
12
12
12
[EXT]
[EXT]
[EXT]
Defaults
Run
Mode
–FE
–FU
–F
Edit
(CE)
(UL)
(Jpn)
00
00
00
00
00
00
00
00
00
Units
Units

Hide quick links: