Utility Specifications - Blodgett BCM Installation & Operation Manual

Blodgett combi oven installation - operation - maintenance
Table of Contents

Advertisement

WATeR
Water pressure
Water connection
Water quality requirements
DRAinAGe
Drain type
Drain connection
Maximum water drain temperature
Model
BLCM-61G
BLCM-101G
BLCM-102G
BLCM-62G
BLCM-202G
PLUMBinG sPeCiFiCATions
36.26 PSI (250 kPa, 2.5 bar) during Combi Wash
21.76 PSI (150 kPa, 1.5 bar) when Combi Wash is not active
40(min)-50(max) PSI supply pressure
3/4" garden hose cold water
TDS: 40-125 ppm
Hardness: 35-100 ppm
Chlorides: <25 ppm
Silica: <13 ppm
Chlorine: 0 ppm
pH: 7.0-8.5
Atmospheric Vented Drain
2.00" (50.8mm) Copper
140ºF (60ºC)
RATinGs - GAs ovens
Gas Type
input
Natural
58,000 BTU
Propane
58,000 BTU
Natural
87,000 BTU
Propane
87,000 BTU
Natural
95,500 BTU
Propane
95,500 BTU
Natural
81,800 BTU
Propane
81,800 BTU
Natural
190,000 BTU
Propane
190,000 BTU
voltage
115
115
115
115
115
115
115
115
115
115
5
Installation

Utility Specifications

Phase
Amps
1
1
1
1
1
1
1
1
1
17
1
17
9
9
9
9
9
9
9
9

Hide quick links: