HYDROPOOL SERENITY SERIES CONTROL SYSTEMS
INITIAL START-UP
Before applying voltage to power-up your hot tub, it is very
important that you understand the sequence of events that
occur when the system is activated in order that the pump
can be primed efficiently and damage to the system can be
avoided.
At initial power-up, this display will appear, and the system
will show 4 sets of numbers in succession as follows (M100,
_200, V6 and 240V). These numbers represent the current
software revision, and the system input voltage. After the
initial software indicators are shown, the display will flash
"LINK". This refers to "linking" the TP600 control panel with
the system and is done by pressing any key on the control.
After this is done the display will show "RUN PMPS PURG
AIR". This display is indicating that the system is in PUMP
PRIMING MODE. This mode will last for 4 minutes before
automatically exiting and entering the normal operation
mode. You can also manually exit PUMP PRIMING MODE
by pressing any TEMP button.
While in this mode, the heater circuit is disabled to allow the
priming process to be completed without the possibility of
energizing the heater element during low flow or no flow
conditions. The system will not automatically activate any of
the functions, however, by pushing the pad on the topside
control, the pump can be manually activated to facilitate
priming.
DEFINITION: 'Priming' a pump is a term used to describe
the process in which air trapped in the plumbing and pump
wet-end (referred to as an 'air lock') is released, allowing the
pump to move water efficiently through the plumbing system
and to the jets.
PUMP PRIMING MODE
As soon as "RUN PMPS PURG AIR" is indicated on the
topside panel, push the pad to start Pump 1 in low speed,
then again to switch to high speed to facilitate priming. See
FILLING, CHECKING AND STARTING YOUR HOT TUB
for complete instructions on pump priming.
Once pump priming has been successfully completed, press
the pad to turn off the pump.
Next, manually exit PRIMING MODE by pressing any
"TEMP" button. If you do not manually exit PRIMING
MODE, it will automatically terminate after 4 minutes. Be
sure that the pump is primed before exiting this mode.

NORTH AMERICA / EUROPE

HYDROPOOL SERENITY – ALL SERIES
SET TIME
After the system exits PRIMING MODE, it will ask you to
"SET TIME". See the instructions on the following pages.
After you manually exit or the system automatically exits
Priming Mode, your hot tub will automatically heat to the
factory preset default temperature of 38°C (100°F) The top-
side panel will briefly show the default temperature, and
then the display will appear as follows:
Note that the water temperature is not yet displayed, as the
system requires approximately 2 minutes of water flow
through the heater to determine temperature. This is re-
ferred to as 'polling' and is indicated on the display by the
icon. After 2 minutes the display will show the current meas-
ured water temperature.
Press the pad to increase the temperature to the desired
setting. The Heat indicator light on the Topside Panel will
shimmer for 90 seconds, indicating that the system is not
yet heating, then will illuminate solidly to indicate that the
heater circuit has been energized and the spa water is being
heated.
In Standard Operating Mode, the system automatically acti-
vates Pump 1 low speed every 30 minutes for at least 2
minutes.
After 2 minutes, the spa water temperature is determined. At
this point, if the water temperature is lower than the set tem-
perature, P1 will continue to run and the Heat indicator light
on the Topside Panel will illuminate. The heater will operate
until the water temperature reaches the set temperature
point, after which, both the heater and Pump 1 low will auto-
matically turn off.
TO CHECK/CHANGE THE SET TEMPERATURE
The last measured temperature is constantly displayed on
the topside panel. When this pad is pressed once any time
during normal operation, the display will show the set tem-
perature for 3 seconds. Press this pad a second time to
increase or decrease the set temperature. To change the
direction of the temperature settings (ie. lower vs. raise the
temperature), allow the display to revert back to the current
water temperature then press the pad again.
TEMPERATURE RANGES
High Range can be set between 27°C (80°F) and 40°C
(104°F) in 1° increments.
Low Range can be set between 10°C (50°F) and 37°C (99°
F) in 1° increments.
HEATER FUNCTION
The heater operates with pump low-speed only, and turns
off when ever pump high-speed or blower is activated.