Needle In Needle Hole Center (Only On Pfaff 1183) - Pfaff 1181 Adjustment Manual

Table of Contents

Advertisement

13
Needle in needle hole center
.05.09
Requirement
The needle must penetrate the needle hole exactly in the middle.
Fig. 13 - 10
● Set the needle in the needle hole.
● Loosen screws 1, 2 and 3.
● Move the needle bar frame 4 according to the requirement.
● Tighten screw 2 and turn screw 3 slightly.
● Via screw 1, bring the retracted guide bolt to the eye of the needle bar frame 4 and
tighten it.
● Turn the handwheel a few times to prevent distortion to the needle bar frame 4.
● Tighten screw 3.
(only on PFAFF 1183)
4
Adjustment
1
3
2
13 - 11