If the treadmill being serviced operates on 120Vac, the 120Vac jumper must be removed
from the defective lower power PCA and re-installed on the replacement lower power PCA
between the M1 connector and the M6 connector.
Caution
If the treadmill being serviced operates on 240 Vac, the jumper in step 12 must not be
installed. If the jumper is installed and the treadmill is operated on 240 Vac, the lower power
PCA will be operated on double the intended voltage. Damage to the lower power PCA will
result.
8.
Set the treadmill circuit breaker in the "on" position and check treadmill operation per
Procedure 3.
Page 1-30