Procedure 6.9 - Replacing The Line Filter - Precor C954 Serivce Manual

Hide thumbs Also See for C954:
Table of Contents

Advertisement

Procedure 6.9 - Replacing the Line Filter

1.
Set the treadmill circuit breaker in the "off" position and unplug the treadmills line cord from
the AC outlet.
2.
Remove the four screws that fasten the circuit breaker mounting plate to the treadmill. See
Diagram 6.10 or 6.11.
3.
Disconnect all of the wiring from the line filter.
4.
Remove the screws that fasten the line filter to the circuit breaker mounting panel.
5.
Set the replacement line filter in its mounting position. Fasten the line filter to the circuit
breaker mounting panel with the screws removed in step 4.
6.
Connect the wiring to the line filter per Diagram 6.13.
Diagram 6.13 - Line Filter Wiring
7.
Set the circuit breaker mounting panel in its mounting position. Fasten the circuit breaker
mounting panel to the treadmill using the screws removed in step 2.
8.
Check treadmill operation per Section 3.